c/kWh
Energy rating (cooling)
3.5
Heating: 3
Annual electricity use
1,563 kWh
565 cooling + 998 heating
Estimated running cost
$500 / year
$42 / month Β· $5,002 over 10 years
Capacity
7.3 kW cooling
8.3 kW heating

2% less electricity than the median of 207 comparable 7 kW reverse cycle split system registrations (1,600 kWh a year) in the mixed zone. Uses less than 64% of them.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 62% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Westinghouse WSD73HWB-I running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,063$980$9,802
Mixed zone 1,563$500$5,002
Hot zone 1,808$579$5,786

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 7.3 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling1,281 kWh/yr4.5$410
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling1,399 kWh/yr3$448
Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W7.7 kW heating7.2 kW cooling1,404 kWh/yr4$449
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling1,421 kWh/yr2.5$455
Kogan KASSSAC71HC7.5 kW heating7.1 kW cooling1,433 kWh/yr4$459

Air conditioners similar to the Westinghouse WSD73HWB-I

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Spt AW073C-1 / AW073E8.1 kW heating7.3 kW cooling1,559 kWh/yr3.5$499
Bonaire CRC6911071/CRC69111717.2 kW heating7.2 kW cooling1,516 kWh/yr3.5$485
Hyundai HYSSSAC72TA7.3 kW heating7.2 kW cooling1,518 kWh/yr3$486
Braemar TCHV70T1S/TSHV70T1S7.2 kW heating7.2 kW cooling1,516 kWh/yr3.5$485
Smart Lifestyle Australia SLA-72-CHSD7.2 kW heating7.2 kW cooling1,516 kWh/yr3.5$485
Domain ISR-72P-OUT/ISR-72P-IND7.2 kW heating7.2 kW cooling1,516 kWh/yr3.5$485
TCL TAC-24CHSD/TPH11IT7.2 kW heating7.2 kW cooling1,516 kWh/yr3.5$485
Ers Tech ERS-AC72F017.2 kW heating7.2 kW cooling1,516 kWh/yr3.5$485

Compare WSD73HWB-I/WSD73HWA-E with another model

Westinghouse WSD73HWB-I specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.30 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
8.30 kW
Heating power input
–
EER, full load (tested)
3.77
COP, full load (tested)
3.94
Rated AEER
3.70
Rated ACOP
4.03
Standby power (PIA)
1.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
58.1 dB(A)
Outdoor sound power
66.1 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Westinghouse WSD73HWB-I zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––696837
Coldresidential4.02.53522,711
Mixedcommercial––923429
Mixedresidential3.53.0565998
Hotcommercial––2,16585
Hotresidential4.03.51,672136
Part-load test points (23 values)
c__t1_min_cap_power_rated
630 W
h__h1_min_cap_power_rated
423 W
h__h2_ext_cap_power_rated
3070 W
c__t1_half_cap_power_rated
675 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
716 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2300 W
h__h2_ext_cap_heat_cap_rated
8400 W
h__h1_half_cap_heat_cap_rated
3850 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
536 W
c__t1_min_cap_cooling_cap_rated
3312 W
c__low_temp_half_cap_power_rated
620 W
c__t1_half_cap_cooling_cap_rated
3500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3800 W
c__low_temp_half_cap_cooling_cap_rated
4190 W

Other model numbers on registration AAC7554

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC7554
GEMS registration id
–
Status
approved
Registration expires
5 June 2028
Registered for sale in
Australia, New Zealand
Family
WSD73HWA-E/WSD73HWA-I
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
9