c/kWh
Energy rating (cooling)
2.5
Heating: 1.5
Annual electricity use
4,944 kWh
643 cooling + 4,301 heating
Estimated running cost
$1,632 / year
$136 / month Β· $16,315 over 10 years
Capacity
10 kW cooling
10.5 kW heating

4% more electricity than the median of 136 comparable 10 kW reverse cycle ducted split system registrations (4,758 kWh a year) in the cold zone. Uses less than 35% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 39% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air CRS10AS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,944$1,632$16,315
Mixed zone 2,598$857$8,573
Hot zone 3,157$1,042$10,418

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ3R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Panasonic U-100PZ3R5 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,660 kWh/yr4$1,208
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,687 kWh/yr3.5$1,217
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling3,713 kWh/yr5$1,225

Heat pumps similar to the Actron Air CRS10AS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R8 / S-100PE4R10 kW heating10 kW cooling3,866 kWh/yr2.5$1,276
Mitsubishi Electric PUZ-ZM100VKA2-A/PEA-M100HAA Series11.2 kW heating10 kW cooling4,393 kWh/yr2.5$1,450
Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling4,227 kWh/yr4.5$1,395
Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling3,866 kWh/yr2.5$1,276
Daikin RZAV100FV1 / FBA100BVMA12 kW heating10 kW cooling4,302 kWh/yr3.5$1,420
Pioneer International VPC-36A1/CPE-36A110 kW heating10 kW cooling4,523 kWh/yr3.5$1,493
Mitsubishi Electric PUZ-ZM100VKA2-A/PEA-M100HAA11.2 kW heating10 kW cooling4,393 kWh/yr2.5$1,450
Daikin RZAV100CV1 / FBA100BVMA11.2 kW heating10 kW cooling4,295 kWh/yr3$1,417

Compare CRS10AS / EVA10AS with another model

Actron Air CRS10AS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
2.97 kW
Rated heating capacity (7 Β°C)
10.52 kW
Heating power input
3.06 kW
EER, full load (tested)
3.28
COP, full load (tested)
3.35
Rated AEER
3.33
Rated ACOP
3.40
Standby power (PIA)
10.1 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Country of manufacture
Australia, China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air CRS10AS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,4061,357
Coldresidential2.51.56434,301
Mixedcommercial––1,766706
Mixedresidential2.52.01,0031,595
Hotcommercial––3,915154
Hotresidential2.52.52,918239
Part-load test points (18 values)
c__t1_half_cap_power_rated
1126 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1131 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
2923 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
5075 W
h__h2_full_cap_heat_cap_rated
8321 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
2714.58 W
c__low_temp_half_cap_power_rated
1029.164 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5018 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
10770 W
c__low_temp_half_cap_cooling_cap_rated
5404.3859999999995 W

New Zealand E3 registration details

Registration number
AAC7719
GEMS registration id
156221
Status
approved, available (self-reported)
Registration expires
19 August 2028
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.