New Zealand Β· costs in NZD

Reverse cycle packaged air conditioner
Actron Air PCG400U Heat Pump
Actron Air PCG400U is a 39.2 kW reverse cycle ducted packaged heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9956).
- Energy rating (cooling)
- 1
- Heating: 0
- Annual electricity use
- 3,697 kWh
- Estimated running cost
- $1,220 / year
- $102 / month Β· $12,200 over 10 years
- Capacity
- 39.2 kW cooling
- 39.5 kW heating
3% less electricity than the median of 13 comparable 40 kW reverse cycle ducted packaged registrations (3,797 kWh a year) in the cold zone. Uses less than 54% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 50% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Actron Air PCG400U running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,697 | $1,220 | $12,200 |
| Mixed zone | 5,544 | $1,830 | $18,295 |
| Hot zone | 16,026 | $5,289 | $52,886 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 39.2 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| APAC P035AHR3SA-31.5 kW heating36 kW cooling2,497 kWh/yr | 2 | $824 | |
| APAC P035AHR3SA-LRR31.5 kW heating36 kW cooling2,497 kWh/yr | 2 | $824 | |
| Caa VPA035R3AC37.4 kW heating34.7 kW cooling2,853 kWh/yr | 1.5 | $941 | |
| Caa HPA035R3AD38.1 kW heating36.3 kW cooling2,881 kWh/yr | 2 | $951 | |
| Temperzone OPA370RKTB35.9 kW heating36.8 kW cooling3,160 kWh/yr | 1.5 | $1,043 |
Heat pumps similar to the Actron Air PCG400U
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| APAC P038AHR3SA-RRR37.7 kW heating39.7 kW cooling3,101 kWh/yr | 1.5 | $1,023 | |
| APAC P038AHR3SA-RBB37.7 kW heating39.7 kW cooling3,101 kWh/yr | 1.5 | $1,023 | |
| Daikin UAYN400AFY1A37.6 kW heating40.8 kW cooling31,483 kWh/yr | 1.5 | $10,389 | |
| Daikin UAYN350AFY1A34.3 kW heating37.2 kW cooling22,636 kWh/yr | 1 | $7,470 | |
| Temperzone OPA 371RLTP36.2 kW heating37 kW cooling20,669 kWh/yr | 1.5 | $6,821 | |
| Temperzone OPA370RKTB35.9 kW heating36.8 kW cooling3,160 kWh/yr | 1.5 | $1,043 | |
| Caa HPA035R3AD38.1 kW heating36.3 kW cooling2,881 kWh/yr | 2 | $951 | |
| AIRSTAGE RAQ/L/EC/WP/11533.9 kW heating36.2 kW cooling18,653 kWh/yr | 1.5 | $6,155 |
Compare PCG400U with another model
Actron Air PCG400U specifications
- Type
- Reverse cycle
- Configuration
- Packaged
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 39.20 kW
- Cooling power input
- 12.76 kW
- Rated heating capacity (7 Β°C)
- 39.50 kW
- Heating power input
- 11.97 kW
- EER, full load (tested)
- 2.97
- COP, full load (tested)
- 3.26
- Rated AEER
- 3.02
- Rated ACOP
- 3.24
- Standby power (PIA)
- 69.2 W
- Compressor
- Variable speed
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes (requires additional part)
- Country of manufacture
- Australia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Actron Air PCG400U zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 8,330 | β |
| Coldresidential | residential | 1.0 | 0.0 | 3,697 | β |
| Mixedcommercial | commercial | β | β | 10,240 | β |
| Mixedresidential | residential | 1.0 | 0.0 | 5,544 | β |
| Hotcommercial | commercial | β | β | 21,963 | β |
| Hotresidential | residential | 1.5 | 0.0 | 16,026 | β |
Part-load test points (1 values)
- c__low_temp_have_full_cap_results
- No
Other model numbers on registration AAC9956
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC9956
- GEMS registration id
- 177567
- Status
- approved, available (self-reported)
- Registration expires
- 25 August 2031
- Registered for sale in
- Australia, New Zealand
- Family
- PCG400
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 7
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.