New Zealand Β· costs in NZD

Reverse cycle packaged air conditioner
Actron Air PRV85AT Heat Pump
Actron Air PRV85AT is a 85 kW reverse cycle ducted packaged heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8989).
- Energy rating (cooling)
- 2.5
- Heating: 1.5
- Annual electricity use
- 41,538 kWh
- 5,475 cooling + 36,063 heating
- Estimated running cost
- $13,708 / year
- $1,142 / month Β· $137,075 over 10 years
- Capacity
- 85 kW cooling
- 86 kW heating
About the same electricity as the median of 53 comparable 80 kW and above reverse cycle ducted packaged registrations (41,538 kWh a year) in the cold zone. Uses less than 49% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 2% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Actron Air PRV85AT running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 41,538 | $13,708 | $137,075 |
| Mixed zone | 21,630 | $7,138 | $71,379 |
| Hot zone | 25,959 | $8,566 | $85,665 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 85 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| APAC P075AHR3SA-RBB72.9 kW heating75.5 kW cooling6,399 kWh/yr | 1.5 | $2,112 | |
| APAC P075AHR3SA-RRR72.9 kW heating75.5 kW cooling6,399 kWh/yr | 1.5 | $2,112 | |
| Temperzone OPA 820RLTB1FPQ79 kW heating78.4 kW cooling6,702 kWh/yr | 1.5 | $2,212 | |
| Temperzone OPA855RKTBG-P77.6 kW heating81.4 kW cooling7,082 kWh/yr | 1.5 | $2,337 |
Heat pumps similar to the Actron Air PRV85AT
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| APAC P085AHR3SA-RBB80.8 kW heating84.1 kW cooling7,214 kWh/yr | 1.5 | $2,381 | |
| APAC P085AHR3SA-80.8 kW heating84.1 kW cooling7,214 kWh/yr | 1.5 | $2,381 | |
| AIRSTAGE RAQ/L/EC/WP/23480.5 kW heating83.7 kW cooling40,796 kWh/yr | 2 | $13,463 | |
| AIRSTAGE RAQ/K/EC/WP/ECO/23484.1 kW heating83.1 kW cooling43,255 kWh/yr | 1.5 | $14,274 | |
| Daikin UAYN840AFY1A82 kW heating81.9 kW cooling49,366 kWh/yr | 1 | $16,291 | |
| Temperzone OPA855RKTBG-P77.6 kW heating81.4 kW cooling7,082 kWh/yr | 1.5 | $2,337 | |
| Temperzone OPA970RLTB1FPQ88.2 kW heating88.9 kW cooling8,214 kWh/yr | 1.5 | $2,711 | |
| Daikin UAYN940AFY1A94 kW heating94.9 kW cooling56,405 kWh/yr | 1 | $18,614 |
Compare PRV85AT with another model
Actron Air PRV85AT specifications
- Type
- Reverse cycle
- Configuration
- Packaged
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 85.00 kW
- Cooling power input
- 25.81 kW
- Rated heating capacity (7 Β°C)
- 86.00 kW
- Heating power input
- 23.91 kW
- EER, full load (tested)
- 3.21
- COP, full load (tested)
- 3.51
- Rated AEER
- 3.23
- Rated ACOP
- 3.53
- Standby power (PIA)
- 140.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Australia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Actron Air PRV85AT zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 8,710 | 11,677 |
| Coldresidential | residential | 2.5 | 1.5 | 5,475 | 36,063 |
| Mixedcommercial | commercial | β | β | 12,496 | 5,852 |
| Mixedresidential | residential | 2.5 | 2.0 | 8,464 | 13,166 |
| Hotcommercial | commercial | β | β | 29,127 | 1,363 |
| Hotresidential | residential | 3.0 | 2.5 | 23,885 | 2,074 |
Part-load test points (18 values)
- h__h2_ext_cap_power_rated
- 22265 W
- c__t1_half_cap_power_rated
- 11443 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 8840 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 62840 W
- h__h1_half_cap_heat_cap_rated
- 39930 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 8155 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 41290 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 41935 W
New Zealand E3 registration details
- Registration number
- AAC8989
- GEMS registration id
- 169020
- Status
- approved, available (self-reported)
- Registration expires
- 12 June 2030
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split >65kW] GEMS (Air Conditioners above 65kW) Determination 2022
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2020
- Product class
- Class 24
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.