c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
5,350 kWh
623 cooling + 4,727 heating
Estimated running cost
$1,766 / year
$147 / month Β· $17,655 over 10 years
Capacity
12.6 kW cooling
14.5 kW heating

13% less electricity than the median of 146 comparable 12.5 kW reverse cycle ducted split system registrations (6,125 kWh a year) in the cold zone. Uses less than 80% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 36% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air URC-125DS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,350$1,766$17,655
Mixed zone 2,760$911$9,108
Hot zone 3,079$1,016$10,161

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 12.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling4,365 kWh/yr4.5$1,440
Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling4,458 kWh/yr3$1,471
Panasonic U-125PZ4R5 / S-125PE4*12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Carrier 38QSM125D8S/42QSM125D8S13 kW heating12.3 kW cooling4,798 kWh/yr3.5$1,583

Heat pumps similar to the Actron Air URC-125DS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai DSNSR13B1LA14.5 kW heating12.6 kW cooling5,350 kWh/yr4$1,766
Midea UCMI125OC/DUCMI125IHC14.5 kW heating12.6 kW cooling5,350 kWh/yr4$1,766
Rinnai DONSR13B1LA/DINLR13B1A14.5 kW heating12.6 kW cooling5,350 kWh/yr4$1,766
Kaden KDI-12.514.5 kW heating12.6 kW cooling5,350 kWh/yr4$1,766
Panasonic U-125PZ4R5 / S-125PE4RN12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Panasonic U-125PZ4R8 / S-125PE4R12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Kaden KDI4213 kW heating12.5 kW cooling4,853 kWh/yr3.5$1,601

Compare URC-125DS / LRE-125DS with another model

Actron Air URC-125DS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
12.60 kW
Cooling power input
3.77 kW
Rated heating capacity (7 Β°C)
14.50 kW
Heating power input
3.55 kW
EER, full load (tested)
3.39
COP, full load (tested)
4.17
Rated AEER
3.32
Rated ACOP
4.05
Standby power (PIA)
9.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air URC-125DS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––6361,495
Coldresidential4.02.56234,727
Mixedcommercial––1,163783
Mixedresidential3.53.09921,768
Hotcommercial––3,076168
Hotresidential4.03.52,818261
Part-load test points (23 values)
c__t1_min_cap_power_rated
920 W
h__h1_min_cap_power_rated
643 W
h__h2_ext_cap_power_rated
5100 W
c__t1_half_cap_power_rated
1780 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1300 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3218 W
h__h2_ext_cap_heat_cap_rated
14580 W
h__h1_half_cap_heat_cap_rated
7020 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
555 W
c__t1_min_cap_cooling_cap_rated
3250 W
c__low_temp_half_cap_power_rated
1080 W
c__t1_half_cap_cooling_cap_rated
6300 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3830 W
c__low_temp_half_cap_cooling_cap_rated
6820 W

New Zealand E3 registration details

Registration number
AAC8934
GEMS registration id
169890
Status
approved, available (self-reported)
Registration expires
29 May 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.