c/kWh
Energy rating (cooling)
4
Heating: 1.5
Annual electricity use
3,474 kWh
358 cooling + 3,116 heating
Estimated running cost
$1,146 / year
$96 / month Β· $11,464 over 10 years
Capacity
7.2 kW cooling
8 kW heating

11% more electricity than the median of 203 comparable 7 kW reverse cycle split system registrations (3,143 kWh a year) in the cold zone. Uses less than 14% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 54% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air WRC-072CS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,474$1,146$11,464
Mixed zone 1,618$534$5,339
Hot zone 1,818$600$5,999

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr3$853
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr3$860
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr5$862
Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr0.5$883
Solar Acdc DGWA1-ACDC-24KR27 kW heating6.4 kW cooling2,743 kWh/yr3$905

Heat pumps similar to the Actron Air WRC-072CS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Braemar TCHV07T1S/TSHV07T1S7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
Bonaire STH072S1AE/STH072S1AI7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
Hyundai HYSSSAC72TB7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
TCL TAC-24CHSD/TPH11IH7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
Braemar TCHV70T1S/TSHV70T1S7.2 kW heating7.2 kW cooling2,905 kWh/yr3.5$959
Bonaire CRC6911071/CRC69111717.2 kW heating7.2 kW cooling2,905 kWh/yr3.5$959
Hyundai HYSSSAC72T*7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
TCL TAC-24CHSD series7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935

Compare WRC-072CS / WRE-072CS with another model

Actron Air WRC-072CS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.20 kW
Cooling power input
1.90 kW
Rated heating capacity (7 Β°C)
8.00 kW
Heating power input
2.05 kW
EER, full load (tested)
3.81
COP, full load (tested)
3.94
Rated AEER
3.78
Rated ACOP
3.90
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
65 dB(A)
Outdoor sound power
69 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air WRC-072CS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––619946
Coldresidential4.01.53583,116
Mixedcommercial––872441
Mixedresidential3.52.55651,053
Hotcommercial––2,14284
Hotresidential4.03.51,685133
Part-load test points (23 values)
c__t1_min_cap_power_rated
715 W
h__h1_min_cap_power_rated
430 W
h__h2_ext_cap_power_rated
2450 W
c__t1_half_cap_power_rated
800 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
740 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2250 W
h__h2_ext_cap_heat_cap_rated
5980 W
h__h1_half_cap_heat_cap_rated
4000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
510 W
c__t1_min_cap_cooling_cap_rated
3450 W
c__low_temp_half_cap_power_rated
630 W
c__t1_half_cap_cooling_cap_rated
3900 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3350 W
c__low_temp_half_cap_cooling_cap_rated
3950 W

New Zealand E3 registration details

Registration number
AAC9190
GEMS registration id
171657
Status
approved, available (self-reported)
Registration expires
9 August 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.