New Zealand Β· costs in NZD

Reverse cycle packaged air conditioner
AIRSTAGE URT-EC-WP-MS-152-SK Heat Pump
AIRSTAGE URT-EC-WP-MS-152-SK is a 169 kW reverse cycle ducted packaged heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9201).
A newer registration of this model exists: AAC9201.
- Energy rating (cooling)
- 1.5
- Heating: 1
- Annual electricity use
- 91,451 kWh
- 15,396 cooling + 76,055 heating
- Estimated running cost
- $30,179 / year
- $2,515 / month Β· $301,788 over 10 years
- Capacity
- 169 kW cooling
- 173 kW heating
120% more electricity than the median of 53 comparable 80 kW and above reverse cycle ducted packaged registrations (41,538 kWh a year) in the cold zone. Uses less than 15% of them.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 0% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
AIRSTAGE URT-EC-WP-MS-152-SK running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 91,451 | $30,179 | $301,788 |
| Mixed zone | 53,597 | $17,687 | $176,870 |
| Hot zone | 74,461 | $24,572 | $245,721 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 169 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| APAC P150AHR3SA-CBR146.6 kW heating156.7 kW cooling13,252 kWh/yr | 1.5 | $4,373 | |
| APAC P150AHR3SA-146.6 kW heating156.7 kW cooling13,252 kWh/yr | 1.5 | $4,373 | |
| Daikin UAXYA170NY1170 kW heating170 kW cooling15,866 kWh/yr | 1 | $5,236 | |
| Daikin UAXYA170RY1170 kW heating170 kW cooling15,866 kWh/yr | 1 | $5,236 | |
| Temperzone OPA2100RKTMDF-P186.7 kW heating178 kW cooling15,908 kWh/yr | 1.5 | $5,250 |
Heat pumps similar to the AIRSTAGE URT-EC-WP-MS-152-SK
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin UAXYA170SY1170 kW heating170 kW cooling15,866 kWh/yr | 1 | $5,236 | |
| Daikin UAXYA170RY1170 kW heating170 kW cooling15,866 kWh/yr | 1 | $5,236 | |
| Temperzone OPA1710RLTM1FPQ170.7 kW heating164.2 kW cooling97,702 kWh/yr | 1.5 | $32,242 | |
| APAC P170AHR3SA-CTR164.5 kW heating173.9 kW cooling15,426 kWh/yr | 1 | $5,091 | |
| APAC P170AHR3SA-CBR164.5 kW heating173.9 kW cooling15,426 kWh/yr | 1 | $5,091 | |
| Carrier 50FC-180 R454b184 kW heating176 kW cooling128,718 kWh/yr | 1.5 | $42,477 | |
| Temperzone OPA1710RLTM4FDPQ184.1 kW heating177.9 kW cooling92,691 kWh/yr | 2.5 | $30,588 | |
| Carrier 50FC-180190 kW heating181 kW cooling123,455 kWh/yr | 1.5 | $40,740 |
Compare URT-EC-WP-MS-152-SK with another model
AIRSTAGE URT-EC-WP-MS-152-SK specifications
- Type
- Reverse cycle
- Configuration
- Packaged
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 169.00 kW
- Cooling power input
- 56.30 kW
- Rated heating capacity (7 Β°C)
- 173.00 kW
- Heating power input
- 47.80 kW
- EER, full load (tested)
- 2.94
- COP, full load (tested)
- 3.54
- Rated AEER
- 3.00
- Rated ACOP
- 3.61
- Standby power (PIA)
- 30.0 W
- Compressor
- Variable speed
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- Italy, Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
AIRSTAGE URT-EC-WP-MS-152-SK zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 35,897 | 25,789 |
| Coldresidential | residential | 1.5 | 1.0 | 15,396 | 76,055 |
| Mixedcommercial | commercial | β | β | 44,322 | 14,018 |
| Mixedresidential | residential | 1.5 | 1.5 | 23,367 | 30,230 |
| Hotcommercial | commercial | β | β | 96,068 | 2,990 |
| Hotresidential | residential | 1.5 | 1.5 | 69,679 | 4,782 |
Part-load test points (4 values)
- h__h2_full_cap_power_rated
- 45900 W
- h__h3_have_full_cap_results
- No
- h__h2_full_cap_heat_cap_rated
- 156000 W
- c__low_temp_have_full_cap_results
- No
Other model numbers on registration AAC9201
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC9201
- GEMS registration id
- 171807
- Status
- approved, available (self-reported)
- Registration expires
- 6 August 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- URT/EC/WP/MS 152
- Regulatory standard
- [SEER Non Multi-Split >65kW] GEMS (Air Conditioners above 65kW) Determination 2022
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2020
- Product class
- Class 24
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: fujitsugeneral.com.au. How the derived figures are calculated.