c/kWh
Energy rating (cooling)
2
Heating: 1
Annual electricity use
13,397 kWh
1,734 cooling + 11,663 heating
Estimated running cost
$4,421 / year
$368 / month Β· $44,210 over 10 years
Capacity
22.8 kW cooling
22.8 kW heating

4% less electricity than the median of 17 comparable 25 kW reverse cycle ducted packaged registrations (14,025 kWh a year) in the cold zone. Uses less than 65% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 10% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

APAC P023AHR3TA-RI2061A running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 13,397$4,421$44,210
Mixed zone 7,060$2,330$23,298
Hot zone 8,260$2,726$27,258

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 22.8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Actron Air PRV22AT23 kW heating22 kW cooling10,306 kWh/yr2.5$3,401
APAC P020AHR3SA-RTR18.9 kW heating22.4 kW cooling11,029 kWh/yr1.5$3,640
APAC P020AHR3SA-LBB18.9 kW heating22.4 kW cooling11,029 kWh/yr1.5$3,640
Actron Air PKV240T-T23.4 kW heating20.8 kW cooling11,136 kWh/yr2$3,675
Temperzone OPA242RKTB22 kW heating22.4 kW cooling12,564 kWh/yr1.5$4,146

Heat pumps similar to the APAC P023AHR3TA-RI2061A

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air PCG233U23.6 kW heating22.9 kW cooling12,680 kWh/yr1.5$4,184
Actron Air PCG233V23.6 kW heating22.9 kW cooling12,680 kWh/yr1.5$4,184
Temperzone OPA242RKTB22 kW heating22.4 kW cooling12,564 kWh/yr1.5$4,146
AIRSTAGE RAQ/IL/EC/WP/11024.3 kW heating23.8 kW cooling13,739 kWh/yr2$4,534
AIRSTAGE RAQ/K/WP/ECO/11024.8 kW heating24.4 kW cooling14,357 kWh/yr1.5$4,738
Temperzone OPA250RLTFPQ26.9 kW heating24.6 kW cooling13,358 kWh/yr2.5$4,408

Other APAC models of similar capacity

ModelStarsEst. cost / yrCompare
APAC P020AHR3SA-RBB18.9 kW heating22.4 kW cooling11,029 kWh/yr1.5$3,640
APAC P020AHR3SA-18.9 kW heating22.4 kW cooling11,029 kWh/yr1.5$3,640

Compare P023AHR3TA-RI2061A with another model

APAC P023AHR3TA-RI2061A specifications

Type
Reverse cycle
Configuration
Packaged
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
22.82 kW
Cooling power input
6.76 kW
Rated heating capacity (7 Β°C)
22.84 kW
Heating power input
6.45 kW
EER, full load (tested)
3.34
COP, full load (tested)
3.42
Rated AEER
3.33
Rated ACOP
3.49
Standby power (PIA)
29.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Australia, Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

APAC P023AHR3TA-RI2061A zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––3,9963,810
Coldresidential2.01.01,73411,663
Mixedcommercial––4,9491,937
Mixedresidential2.01.02,6624,398
Hotcommercial––10,316426
Hotresidential2.01.57,605655
Part-load test points (23 values)
c__t1_min_cap_power_rated
3310 W
h__h1_min_cap_power_rated
3010 W
h__h2_ext_cap_power_rated
5620 W
c__t1_half_cap_power_rated
3490 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
3250 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
10620 W
h__h2_ext_cap_heat_cap_rated
15810 W
h__h1_half_cap_heat_cap_rated
11280 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
3210 W
c__t1_min_cap_cooling_cap_rated
11070 W
c__low_temp_half_cap_power_rated
3140 W
c__t1_half_cap_cooling_cap_rated
12030 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
12820 W
c__low_temp_half_cap_cooling_cap_rated
14100 W

Other model numbers on registration AAC10333

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC10333
GEMS registration id
181224
Status
approved, available (self-reported)
Registration expires
26 July 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
P023AHR3TA-
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 6

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.