New Zealand Β· costs in NZD

Reverse cycle packaged air conditioner
APAC P065AHR3SA-LRR Heat Pump
APAC P065AHR3SA-LRR is a 63.5 kW reverse cycle ducted packaged heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7418).
- Energy rating (cooling)
- 1.5
- Heating: 0
- Annual electricity use
- 4,970 kWh
- Estimated running cost
- $1,640 / year
- $137 / month Β· $16,401 over 10 years
- Capacity
- 63.5 kW cooling
- 62.9 kW heating
86% less electricity than the median of 16 comparable 65 kW reverse cycle ducted packaged registrations (35,446 kWh a year) in the cold zone. Uses less than 94% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 38% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
APAC P065AHR3SA-LRR running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,970 | $1,640 | $16,401 |
| Mixed zone | 7,546 | $2,490 | $24,902 |
| Hot zone | 20,856 | $6,882 | $68,825 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 63.5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| APAC P055AHR3SA-RTT54 kW heating56.1 kW cooling4,561 kWh/yr | 1.5 | $1,505 | |
| APAC P055AHR3SA-LRR54 kW heating56.1 kW cooling4,561 kWh/yr | 1.5 | $1,505 |
Heat pumps similar to the APAC P065AHR3SA-LRR
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin UAYQ210CY1A64 kW heating63.7 kW cooling36,496 kWh/yr | 1.5 | $12,044 | |
| Temperzone OPA 680RLTB1FPQ63.5 kW heating65 kW cooling28,933 kWh/yr | 2 | $9,548 | |
| Temperzone OPA 680RLTB2FPDQ64.5 kW heating65.1 kW cooling29,720 kWh/yr | 3 | $9,808 | |
| AIRSTAGE RAQ/L/EC/WP/22461.4 kW heating61.1 kW cooling34,395 kWh/yr | 1.5 | $11,350 | |
| Daikin UAYN640AFY1A64.9 kW heating66.2 kW cooling39,023 kWh/yr | 1.5 | $12,878 | |
| Actron Air PKY620T62.5 kW heating60.8 kW cooling5,989 kWh/yr | 1 | $1,976 | |
| AIRSTAGE RAQ/K/EC/WP/ECO/22463.1 kW heating60.6 kW cooling37,412 kWh/yr | 1 | $12,346 | |
| Caa HPC055R3AD60.9 kW heating56.4 kW cooling4,931 kWh/yr | 1.5 | $1,627 |
Compare P065AHR3SA-LRR with another model
APAC P065AHR3SA-LRR specifications
- Type
- Reverse cycle
- Configuration
- Packaged
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 63.50 kW
- Cooling power input
- 19.20 kW
- Rated heating capacity (7 Β°C)
- 62.90 kW
- Heating power input
- 17.40 kW
- EER, full load (tested)
- 3.17
- COP, full load (tested)
- 3.45
- Rated AEER
- 3.19
- Rated ACOP
- 3.48
- Standby power (PIA)
- 205.0 W
- Compressor
- Variable speed
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- Australia, Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
APAC P065AHR3SA-LRR zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 10,890 | β |
| Coldresidential | residential | 1.5 | 0.0 | 4,970 | β |
| Mixedcommercial | commercial | β | β | 13,342 | β |
| Mixedresidential | residential | 1.5 | 0.0 | 7,546 | β |
| Hotcommercial | commercial | β | β | 28,269 | β |
| Hotresidential | residential | 2.0 | 0.0 | 20,856 | β |
Part-load test points (8 values)
- c__t1_min_cap_power_rated
- 9690 W
- c__t1_have_min_cap_results
- Yes
- c__low_temp_min_cap_power_rated
- 8840 W
- c__t1_min_cap_cooling_cap_rated
- 40850 W
- c__low_temp_full_cap_power_rated
- 17160 W
- c__low_temp_have_full_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 42690 W
- c__low_temp_full_cap_cooling_cap_rated
- 67930 W
Other model numbers on registration AAC7418
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC7418
- GEMS registration id
- 153268
- Status
- approved, available (self-reported)
- Registration expires
- 11 April 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- P065AHR3SA-
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- Simulation
- MEPS
- 2019
- Product class
- Class 7
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.