c/kWh
Energy rating (cooling)
2
Heating: 1.5
Annual electricity use
8,965 kWh
1,297 cooling + 7,668 heating
Estimated running cost
$2,958 / year
$247 / month Β· $29,585 over 10 years
Capacity
17.8 kW cooling
17.8 kW heating

7% more electricity than the median of 51 comparable 18 kW reverse cycle ducted split system registrations (8,396 kWh a year) in the cold zone. Uses less than 28% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 15% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

APAC S018OVR3TA- running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 8,965$2,958$29,585
Mixed zone 4,897$1,616$16,160
Hot zone 6,170$2,036$20,361

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 17.8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr3.5$2,279
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332
Actron Air LRC-170CS / LRE-170CS17.6 kW heating16.6 kW cooling7,156 kWh/yr4$2,361
Carrier 38QSV170N8/42QSV170N8S18 kW heating17 kW cooling7,212 kWh/yr3.5$2,380

Heat pumps similar to the APAC S018OVR3TA-

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic U-180PZH3R8 / S-180PE4R20 kW heating18 kW cooling8,186 kWh/yr2.5$2,701
Daikin RZAS180DV1 / FDYA180AV120 kW heating18 kW cooling7,987 kWh/yr2.5$2,636
Daikin RZAS180DY1 / FDYA180AV120 kW heating18 kW cooling7,978 kWh/yr2.5$2,633
Mitsubishi Electric PUZ-ZM180VKA-A / PEA-M180LAA20 kW heating18 kW cooling8,484 kWh/yr2.5$2,800
TCL TCD180D1HWHS2-DVO/TCD180D1HWHS2-DVI20 kW heating18 kW cooling8,488 kWh/yr3$2,801
Fujitsu AOTG65LRLA/ARTG65LHTA20 kW heating18 kW cooling7,679 kWh/yr10$2,534
Mitsubishi Electric PUZ-ZM180YKA-A / PEA-M180LAA20 kW heating18 kW cooling8,483 kWh/yr2.5$2,799
Panasonic U-180PZH3R5 / S-180PE4R20 kW heating18 kW cooling8,186 kWh/yr2.5$2,701

Compare S018OVR3TA- / S018ILR1TA- with another model

APAC S018OVR3TA- specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
17.78 kW
Cooling power input
5.27 kW
Rated heating capacity (7 Β°C)
17.78 kW
Heating power input
4.45 kW
EER, full load (tested)
3.25
COP, full load (tested)
3.83
Rated AEER
3.31
Rated ACOP
3.91
Standby power (PIA)
29.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Australia, Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

APAC S018OVR3TA- zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,7642,622
Coldresidential2.01.51,2977,668
Mixedcommercial––3,4741,374
Mixedresidential2.01.51,9812,916
Hotcommercial––7,592328
Hotresidential2.52.05,674496
Part-load test points (23 values)
c__t1_min_cap_power_rated
2350 W
h__h1_min_cap_power_rated
2020 W
h__h2_ext_cap_power_rated
4470 W
c__t1_half_cap_power_rated
2350 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
2210 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
7400 W
h__h2_ext_cap_heat_cap_rated
13470 W
h__h1_half_cap_heat_cap_rated
8580 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
2070 W
c__t1_min_cap_cooling_cap_rated
8770 W
c__low_temp_half_cap_power_rated
2070 W
c__t1_half_cap_cooling_cap_rated
8770 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
9340 W
c__low_temp_half_cap_cooling_cap_rated
9340 W

New Zealand E3 registration details

Registration number
AAC10263
GEMS registration id
180558
Status
approved, available (self-reported)
Registration expires
25 June 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.