New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
APAC S018OVR3TA- / S018ILR1TA- Heat Pump
APAC S018OVR3TA- / S018ILR1TA- is a 17.8 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC10263).
- Energy rating (cooling)
- 2
- Heating: 1.5
- Annual electricity use
- 8,965 kWh
- 1,297 cooling + 7,668 heating
- Estimated running cost
- $2,958 / year
- $247 / month Β· $29,585 over 10 years
- Capacity
- 17.8 kW cooling
- 17.8 kW heating
7% more electricity than the median of 51 comparable 18 kW reverse cycle ducted split system registrations (8,396 kWh a year) in the cold zone. Uses less than 28% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 15% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
APAC S018OVR3TA- running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 8,965 | $2,958 | $29,585 |
| Mixed zone | 4,897 | $1,616 | $16,160 |
| Hot zone | 6,170 | $2,036 | $20,361 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 17.8 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr | 3.5 | $2,279 | |
| Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr | 4 | $2,332 | |
| Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr | 4 | $2,332 | |
| Actron Air LRC-170CS / LRE-170CS17.6 kW heating16.6 kW cooling7,156 kWh/yr | 4 | $2,361 | |
| Carrier 38QSV170N8/42QSV170N8S18 kW heating17 kW cooling7,212 kWh/yr | 3.5 | $2,380 |
Heat pumps similar to the APAC S018OVR3TA-
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-180PZH3R8 / S-180PE4R20 kW heating18 kW cooling8,186 kWh/yr | 2.5 | $2,701 | |
| Daikin RZAS180DV1 / FDYA180AV120 kW heating18 kW cooling7,987 kWh/yr | 2.5 | $2,636 | |
| Daikin RZAS180DY1 / FDYA180AV120 kW heating18 kW cooling7,978 kWh/yr | 2.5 | $2,633 | |
| Mitsubishi Electric PUZ-ZM180VKA-A / PEA-M180LAA20 kW heating18 kW cooling8,484 kWh/yr | 2.5 | $2,800 | |
| TCL TCD180D1HWHS2-DVO/TCD180D1HWHS2-DVI20 kW heating18 kW cooling8,488 kWh/yr | 3 | $2,801 | |
| Fujitsu AOTG65LRLA/ARTG65LHTA20 kW heating18 kW cooling7,679 kWh/yr | 10 | $2,534 | |
| Mitsubishi Electric PUZ-ZM180YKA-A / PEA-M180LAA20 kW heating18 kW cooling8,483 kWh/yr | 2.5 | $2,799 | |
| Panasonic U-180PZH3R5 / S-180PE4R20 kW heating18 kW cooling8,186 kWh/yr | 2.5 | $2,701 |
Compare S018OVR3TA- / S018ILR1TA- with another model
APAC S018OVR3TA- specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 17.78 kW
- Cooling power input
- 5.27 kW
- Rated heating capacity (7 Β°C)
- 17.78 kW
- Heating power input
- 4.45 kW
- EER, full load (tested)
- 3.25
- COP, full load (tested)
- 3.83
- Rated AEER
- 3.31
- Rated ACOP
- 3.91
- Standby power (PIA)
- 29.8 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- Australia, Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
APAC S018OVR3TA- zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 2,764 | 2,622 |
| Coldresidential | residential | 2.0 | 1.5 | 1,297 | 7,668 |
| Mixedcommercial | commercial | β | β | 3,474 | 1,374 |
| Mixedresidential | residential | 2.0 | 1.5 | 1,981 | 2,916 |
| Hotcommercial | commercial | β | β | 7,592 | 328 |
| Hotresidential | residential | 2.5 | 2.0 | 5,674 | 496 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 2350 W
- h__h1_min_cap_power_rated
- 2020 W
- h__h2_ext_cap_power_rated
- 4470 W
- c__t1_half_cap_power_rated
- 2350 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 2210 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 7400 W
- h__h2_ext_cap_heat_cap_rated
- 13470 W
- h__h1_half_cap_heat_cap_rated
- 8580 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 2070 W
- c__t1_min_cap_cooling_cap_rated
- 8770 W
- c__low_temp_half_cap_power_rated
- 2070 W
- c__t1_half_cap_cooling_cap_rated
- 8770 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 9340 W
- c__low_temp_half_cap_cooling_cap_rated
- 9340 W
New Zealand E3 registration details
- Registration number
- AAC10263
- GEMS registration id
- 180558
- Status
- approved, available (self-reported)
- Registration expires
- 25 June 2031
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.