c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
7,156 kWh
803 cooling + 6,353 heating
Estimated running cost
$2,361 / year
$197 / month Β· $23,615 over 10 years
Capacity
16.6 kW cooling
17.6 kW heating

10% less electricity than the median of 71 comparable 16 kW reverse cycle ducted split system registrations (7,959 kWh a year) in the cold zone. Uses less than 97% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 24% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air LRC-170CS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 7,156$2,361$23,615
Mixed zone 3,556$1,173$11,735
Hot zone 3,787$1,250$12,497

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 16.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr2$1,483
Actron Air CRV15BT / EVV15BS15 kW heating14.8 kW cooling6,561 kWh/yr2.5$2,165
Actron Air CRV15BT / EAA15BS & EFV15BS15 kW heating14.8 kW cooling6,561 kWh/yr2.5$2,165
Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr3.5$2,279

Heat pumps similar to the Actron Air LRC-170CS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Braemar KCDB195D1B/KGDB195A1S17.9 kW heating16.5 kW cooling7,842 kWh/yr3$2,588
Pioneer International VPC-60D1/VPE-60A1/CPE-60A116 kW heating16.3 kW cooling7,683 kWh/yr3.5$2,535
Pioneer International VPE-60A1/VPC-60D116 kW heating16.3 kW cooling7,683 kWh/yr3.5$2,535
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332
Carrier 38QSV170N8/42QSV170N8S18 kW heating17 kW cooling7,212 kWh/yr3.5$2,380
Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr3.5$2,279
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332
Rinnai DSNSR18B1TA18 kW heating17 kW cooling7,212 kWh/yr3.5$2,380

Compare LRC-170CS / LRE-170CS with another model

Actron Air LRC-170CS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
16.60 kW
Cooling power input
4.93 kW
Rated heating capacity (7 Β°C)
17.60 kW
Heating power input
4.39 kW
EER, full load (tested)
3.30
COP, full load (tested)
3.92
Rated AEER
3.34
Rated ACOP
3.97
Standby power (PIA)
13.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air LRC-170CS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2351,927
Coldresidential4.02.08036,353
Mixedcommercial––1,087964
Mixedresidential3.52.51,2922,264
Hotcommercial––2,486205
Hotresidential4.53.53,464323
Part-load test points (20 values)
c__t1_min_cap_power_rated
1129 W
h__h1_min_cap_power_rated
772 W
h__h2_ext_cap_power_rated
4870 W
c__t1_half_cap_power_rated
2723 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1738 W
h__h1_have_min_cap_results
Yes
h__h1_min_cap_heat_cap_rated
4110 W
h__h2_ext_cap_heat_cap_rated
14125 W
h__h1_half_cap_heat_cap_rated
8685 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
661 W
c__t1_min_cap_cooling_cap_rated
4660 W
c__low_temp_full_cap_power_rated
4506.02 W
c__low_temp_half_cap_power_rated
1335 W
c__t1_half_cap_cooling_cap_rated
7990 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
4120 W
c__low_temp_full_cap_cooling_cap_rated
17878.2 W
c__low_temp_half_cap_cooling_cap_rated
8190 W

New Zealand E3 registration details

Registration number
AAC6912
GEMS registration id
146414
Status
approved, available (self-reported)
Registration expires
30 August 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11