c/kWh
Energy rating (cooling)
3
Heating: 1.5
Annual electricity use
7,842 kWh
978 cooling + 6,864 heating
Estimated running cost
$2,588 / year
$216 / month Β· $25,879 over 10 years
Capacity
16.5 kW cooling
17.9 kW heating

1% less electricity than the median of 71 comparable 16 kW reverse cycle ducted split system registrations (7,959 kWh a year) in the cold zone. Uses less than 63% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 19% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Braemar KCDB195D1B running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 7,842$2,588$25,879
Mixed zone 3,994$1,318$13,180
Hot zone 4,932$1,628$16,276

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 16.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr2$1,483
Actron Air CRV15BT / EAA15BS & EFV15BS15 kW heating14.8 kW cooling6,561 kWh/yr2.5$2,165
Actron Air CRV15BT / EVV15BS15 kW heating14.8 kW cooling6,561 kWh/yr2.5$2,165
Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr3.5$2,279
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332

Heat pumps similar to the Braemar KCDB195D1B

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air LRC-170CS / LRE-170CS17.6 kW heating16.6 kW cooling7,156 kWh/yr4$2,361
Pioneer International VPE-60A1/VPC-60D116 kW heating16.3 kW cooling7,683 kWh/yr3.5$2,535
Pioneer International VPC-60D1/VPE-60A1/CPE-60A116 kW heating16.3 kW cooling7,683 kWh/yr3.5$2,535
Actron Air CRV17AS / EAA17AS & EFV17AS18 kW heating16.8 kW cooling10,288 kWh/yr3$3,395
APAC S015OVR3SA / S015IVR3SA-TR14.2 kW heating16 kW cooling7,837 kWh/yr1.5$2,586
APAC S015OVR3SA / S015ILR1SA-TR14.2 kW heating16 kW cooling7,837 kWh/yr1.5$2,586
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332
Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr3.5$2,279

Compare KCDB195D1B/KGDB195A1S with another model

Braemar KCDB195D1B specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
16.50 kW
Cooling power input
5.05 kW
Rated heating capacity (7 Β°C)
17.90 kW
Heating power input
5.43 kW
EER, full load (tested)
3.28
COP, full load (tested)
3.26
Rated AEER
3.25
Rated ACOP
3.28
Standby power (PIA)
8.3 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
69.5 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China, Australia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Braemar KCDB195D1B zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,9872,153
Coldresidential3.01.59786,864
Mixedcommercial––2,5591,041
Mixedresidential2.52.01,5392,455
Hotcommercial––6,106210
Hotresidential3.03.04,601331
Part-load test points (21 values)
c__t1_min_cap_power_rated
880 W
h__h1_min_cap_power_rated
920 W
h__h2_ext_cap_power_rated
4540 W
c__t1_half_cap_power_rated
1730 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1760 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
4550 W
h__h2_ext_cap_heat_cap_rated
13700 W
h__h1_half_cap_heat_cap_rated
8800 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
755 W
c__t1_min_cap_cooling_cap_rated
4450 W
c__t1_half_cap_cooling_cap_rated
8000 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
4650 W

New Zealand E3 registration details

Registration number
AAC10029
GEMS registration id
178522
Status
approved, available (self-reported)
Registration expires
1 April 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: gree.com. How the derived figures are calculated.