c/kWh
Energy rating (cooling)
3.5
Heating: 1.5
Annual electricity use
7,683 kWh
874 cooling + 6,809 heating
Estimated running cost
$2,535 / year
$211 / month Β· $25,354 over 10 years
Capacity
16.3 kW cooling
16 kW heating

3% less electricity than the median of 71 comparable 16 kW reverse cycle ducted split system registrations (7,959 kWh a year) in the cold zone. Uses less than 73% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 21% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Pioneer International CPE-60A1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 7,683$2,535$25,354
Mixed zone 3,806$1,256$12,560
Hot zone 4,454$1,470$14,698

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 16.3 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr2$1,483
Actron Air CRV15BT / EVV15BS15 kW heating14.8 kW cooling6,561 kWh/yr2.5$2,165
Actron Air CRV15BT / EAA15BS & EFV15BS15 kW heating14.8 kW cooling6,561 kWh/yr2.5$2,165
Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr3.5$2,279
Hisense AUW-140U4RH1/AUD-140UX4RSH117 kW heating14.5 kW cooling6,926 kWh/yr3$2,286

Heat pumps similar to the Pioneer International CPE-60A1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Braemar KCDB195D1B/KGDB195A1S17.9 kW heating16.5 kW cooling7,842 kWh/yr3$2,588
APAC S015OVR3SA / S015ILR1SA-TR14.2 kW heating16 kW cooling7,837 kWh/yr1.5$2,586
APAC S015OVR3SA / S015ILR1SA-FR14.2 kW heating16 kW cooling7,837 kWh/yr1.5$2,586
Panasonic U-160PZH3R8 / S-160PE4RA18 kW heating16 kW cooling7,357 kWh/yr2.5$2,428
Panasonic U-160PZH3R5 / S-160PE4R18 kW heating16 kW cooling7,357 kWh/yr2.5$2,428
Braemar KCHA160D1B/KDHA160D1S18 kW heating16 kW cooling7,395 kWh/yr3.5$2,440
TECO TDS-TSO160HVSWDG18 kW heating16 kW cooling7,395 kWh/yr3.5$2,440
Gree GUD160W1/NhC-S / GUD160PHS1/C-S18 kW heating16 kW cooling7,395 kWh/yr3.5$2,440

Compare CPE-60A1/VPC-60D1 with another model

Pioneer International CPE-60A1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
16.29 kW
Cooling power input
4.63 kW
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
4.65 kW
EER, full load (tested)
3.61
COP, full load (tested)
3.50
Rated AEER
3.51
Rated ACOP
3.44
Standby power (PIA)
2.0 W
Compressor
Variable speed, Inverter
Refrigerant
M60
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Dimensions (WΓ—HΓ—D)
1390 Γ— 280 Γ— 715 mm
Country of manufacture
Australia, China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Pioneer International CPE-60A1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,9291,992
Coldresidential3.51.58746,809
Mixedcommercial––2,456985
Mixedresidential3.02.01,3982,408
Hotcommercial––5,563182
Hotresidential3.53.04,161293
Part-load test points (18 values)
c__t1_half_cap_power_rated
1545 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1472 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
5088 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
7590 W
h__h2_full_cap_heat_cap_rated
11798 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
4231.82 W
c__low_temp_half_cap_power_rated
1412.13 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
8192 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
17544.329999999998 W
c__low_temp_half_cap_cooling_cap_rated
8822.784 W

Other model numbers on registration AAC7409

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC7409
GEMS registration id
152924
Status
approved, available (self-reported)
Registration expires
4 April 2028
Registered for sale in
Australia, New Zealand
Family
VPC-60D1/VPE-60A1/CPE-60A1
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.