c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
6,926 kWh
836 cooling + 6,090 heating
Estimated running cost
$2,286 / year
$190 / month Β· $22,856 over 10 years
Capacity
14.5 kW cooling
17 kW heating

2% more electricity than the median of 124 comparable 14 kW reverse cycle ducted split system registrations (6,763 kWh a year) in the cold zone. Uses less than 40% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 25% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Hisense AUW-140U4RH1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,926$2,286$22,856
Mixed zone 3,533$1,166$11,659
Hot zone 4,182$1,380$13,801

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr2$1,483
Actron Air URC-125CS / LRE-125CS13.4 kW heating12.9 kW cooling4,905 kWh/yr3.5$1,619
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling5,308 kWh/yr5$1,752
Kaden KDI48 / KDI4814 kW heating14 kW cooling5,394 kWh/yr4$1,780
Actron Air URC-140CS / LRE-140CS14.3 kW heating14 kW cooling5,513 kWh/yr4$1,819

Heat pumps similar to the Hisense AUW-140U4RH1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Temperzone OSAT 145RLSFH / ISDT 145LY17 kW heating14.5 kW cooling7,289 kWh/yr2.5$2,405
Temperzone ISD 171LYX / OSA 171RLTFH14.9 kW heating14.5 kW cooling8,580 kWh/yr1.5$2,831
Actron Air CRV15AS / EAA15AS & EFV15AS15.5 kW heating14.4 kW cooling8,459 kWh/yr2.5$2,791
Actron Air CRV15AS / EVV15AS - EXV SE15.5 kW heating14.4 kW cooling8,459 kWh/yr2.5$2,791
Kaden KDI48 / KDI4814 kW heating14 kW cooling5,394 kWh/yr4$1,780
Midea DUCMI140IHB/UCMI140OB14.5 kW heating14 kW cooling5,596 kWh/yr4$1,847
Rinnai DONSR15B1/DINLR15B114.5 kW heating14 kW cooling5,618 kWh/yr4$1,854
Mdv C-UV-140N8-QC3W / CDV-140A6N8-QC3W14.5 kW heating14 kW cooling5,607 kWh/yr3.5$1,850

Compare AUW-140U4RH1/AUD-140UX4RSH1 with another model

Hisense AUW-140U4RH1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.50 kW
Cooling power input
4.08 kW
Rated heating capacity (7 Β°C)
17.00 kW
Heating power input
4.25 kW
EER, full load (tested)
3.51
COP, full load (tested)
4.21
Rated AEER
3.52
Rated ACOP
3.97
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hisense AUW-140U4RH1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,8261,925
Coldresidential3.02.08366,090
Mixedcommercial––2,306987
Mixedresidential3.02.51,3162,217
Hotcommercial––5,158210
Hotresidential3.03.03,854328
Part-load test points (20 values)
h__h2_ext_cap_power_rated
4570 W
c__t1_half_cap_power_rated
1450 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1660 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
14000 W
h__h1_half_cap_heat_cap_rated
8500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
3733.69 W
c__low_temp_half_cap_power_rated
1325.3 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
7250 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
15616.5 W
c__low_temp_half_cap_cooling_cap_rated
7808.25 W

New Zealand E3 registration details

Registration number
AAC8071
GEMS registration id
159515
Status
approved, available (self-reported)
Registration expires
26 February 2029
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: global.hisense.com. How the derived figures are calculated.