c/kWh
Energy rating (cooling)
1.5
Heating: 1
Annual electricity use
8,580 kWh
1,252 cooling + 7,328 heating
Estimated running cost
$2,831 / year
$236 / month Β· $28,314 over 10 years
Capacity
14.5 kW cooling
14.9 kW heating

27% more electricity than the median of 124 comparable 14 kW reverse cycle ducted split system registrations (6,763 kWh a year) in the cold zone. Uses less than 2% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 16% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Temperzone ISD 171LYX running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 8,580$2,831$28,314
Mixed zone 4,791$1,581$15,810
Hot zone 6,005$1,982$19,817

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr2$1,483
Actron Air URC-125CS / LRE-125CS13.4 kW heating12.9 kW cooling4,905 kWh/yr3.5$1,619
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling5,308 kWh/yr5$1,752
Kaden KDI48 / KDI4814 kW heating14 kW cooling5,394 kWh/yr4$1,780
Actron Air URC-140CS / LRE-140CS14.3 kW heating14 kW cooling5,513 kWh/yr4$1,819

Heat pumps similar to the Temperzone ISD 171LYX

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hisense AUW-140U4RH1/AUD-140UX4RSH117 kW heating14.5 kW cooling6,926 kWh/yr3$2,286
Actron Air CRV15AS / EAA15AS & EFV15AS15.5 kW heating14.4 kW cooling8,459 kWh/yr2.5$2,791
Actron Air CRV15AS / EVV15AS - EXV SE15.5 kW heating14.4 kW cooling8,459 kWh/yr2.5$2,791
Midea DUCMI140IHB/UCMI140OB14.5 kW heating14 kW cooling5,596 kWh/yr4$1,847
Kaden KDI48 / KDI4814 kW heating14 kW cooling5,394 kWh/yr4$1,780
Rinnai DONSR15B1/DINLR15B114.5 kW heating14 kW cooling5,618 kWh/yr4$1,854
Mdv C-UV-140N8-QC3W / CDV-140A6N8-QC3W14.5 kW heating14 kW cooling5,607 kWh/yr3.5$1,850

Other Temperzone models of similar capacity

ModelStarsEst. cost / yrCompare
Temperzone OSAT 145RLSFH / ISDT 145LY17 kW heating14.5 kW cooling7,289 kWh/yr2.5$2,405

Compare ISD 171LYX / OSA 171RLTFH with another model

Temperzone ISD 171LYX specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.46 kW
Cooling power input
4.44 kW
Rated heating capacity (7 Β°C)
14.90 kW
Heating power input
4.35 kW
EER, full load (tested)
3.26
COP, full load (tested)
3.43
Rated AEER
3.22
Rated ACOP
3.39
Standby power (PIA)
13.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Australia, New Zealand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Temperzone ISD 171LYX zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,8672,448
Coldresidential1.51.01,2527,328
Mixedcommercial––3,5311,323
Mixedresidential1.51.01,8882,903
Hotcommercial––7,611295
Hotresidential1.51.05,538467
Part-load test points (4 values)
h__h2_full_cap_power_rated
4096 W
h__h3_have_full_cap_results
No
h__h2_full_cap_heat_cap_rated
11973 W
c__low_temp_have_full_cap_results
No

New Zealand E3 registration details

Registration number
AAC8609
GEMS registration id
167384
Status
approved, available (self-reported)
Registration expires
24 February 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.