c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
5,394 kWh
677 cooling + 4,717 heating
Estimated running cost
$1,780 / year
$148 / month Β· $17,800 over 10 years
Capacity
14 kW cooling
14 kW heating

20% less electricity than the median of 124 comparable 14 kW reverse cycle ducted split system registrations (6,763 kWh a year) in the cold zone. Uses less than 98% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 36% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kaden KDI48 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,394$1,780$17,800
Mixed zone 2,861$944$9,441
Hot zone 3,366$1,111$11,108

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr2$1,483
Panasonic U-125PZ4R5 / S-125PE4*12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Panasonic U-125PZ4R8 / S-125PE4R12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling4,830 kWh/yr4$1,594

Heat pumps similar to the Kaden KDI48

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air URC-140CS / LRE-140CS14.3 kW heating14 kW cooling5,513 kWh/yr4$1,819
Actron Air URC-140DS / LRE-140DS15.5 kW heating14 kW cooling5,768 kWh/yr4$1,903
Mdv C-UV-140N8-QC3W / CDV-140HFN8-QC3W14.5 kW heating14 kW cooling5,664 kWh/yr4$1,869
Carrier 38QSV140N8E/42QSV140N8H15.5 kW heating14 kW cooling5,768 kWh/yr4$1,903
Mdv C-UV-140N8-QC3W / CDV-140A6N8-QC3W14.5 kW heating14 kW cooling5,607 kWh/yr3.5$1,850
Rinnai DONSR15B1/DINLR15B114.5 kW heating14 kW cooling5,618 kWh/yr4$1,854
Midea UCMI140OB/DUCMI140IHB14.5 kW heating14 kW cooling5,658 kWh/yr4$1,867
Midea DUCMI140IHB/UCMI140OB14.5 kW heating14 kW cooling5,596 kWh/yr4$1,847

Compare KDI48 / KDI48 with another model

Kaden KDI48 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
4.20 kW
Rated heating capacity (7 Β°C)
14.00 kW
Heating power input
3.46 kW
EER, full load (tested)
3.32
COP, full load (tested)
4.04
Rated AEER
3.31
Rated ACOP
4.01
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
71 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kaden KDI48 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––6511,481
Coldresidential4.02.06774,717
Mixedcommercial––1,246773
Mixedresidential3.52.51,0851,776
Hotcommercial––3,372168
Hotresidential4.03.03,103263
Part-load test points (25 values)
c__t1_min_cap_power_rated
890 W
h__h1_min_cap_power_rated
560 W
h__h2_ext_cap_power_rated
5060 W
c__t1_half_cap_power_rated
1730 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1300 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2800 W
h__h2_ext_cap_heat_cap_rated
14150 W
h__h1_half_cap_heat_cap_rated
6500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
530 W
c__t1_min_cap_cooling_cap_rated
3210 W
c__low_temp_full_cap_power_rated
3838.8 W
c__low_temp_half_cap_power_rated
1095 W
c__t1_half_cap_cooling_cap_rated
6550 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3770 W
c__low_temp_full_cap_cooling_cap_rated
15078 W
c__low_temp_half_cap_cooling_cap_rated
7100 W

New Zealand E3 registration details

Registration number
AAC7203
GEMS registration id
151481
Status
approved, available (self-reported)
Registration expires
11 December 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: reece.com.au. How the derived figures are calculated.