c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
5,664 kWh
681 cooling + 4,983 heating
Estimated running cost
$1,869 / year
$156 / month Β· $18,691 over 10 years
Capacity
14 kW cooling
14.5 kW heating

16% less electricity than the median of 124 comparable 14 kW reverse cycle ducted split system registrations (6,763 kWh a year) in the cold zone. Uses less than 89% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 34% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Mdv running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,664$1,869$18,691
Mixed zone 2,951$974$9,738
Hot zone 3,389$1,118$11,184

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr2$1,483
Panasonic U-125PZ4R8 / S-125PE4*12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Panasonic U-125PZ4R8 / S-125PE4RN12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling4,830 kWh/yr4$1,594

Heat pumps similar to the Mdv

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kaden KDI-14.015.5 kW heating14 kW cooling5,768 kWh/yr4$1,903
Kaden KDI48 / KDI4814 kW heating14 kW cooling5,394 kWh/yr4$1,780
Midea DUCMI140IHB/UCMI140OB14.5 kW heating14 kW cooling5,596 kWh/yr4$1,847
Actron Air URC-140CS / LRE-140CS14.3 kW heating14 kW cooling5,513 kWh/yr4$1,819
Actron Air URC-140DS / LRE-140DS15.5 kW heating14 kW cooling5,768 kWh/yr4$1,903
Rinnai DONSR15B1/DINLR15B114.5 kW heating14 kW cooling5,618 kWh/yr4$1,854
Carrier 38QSV140N8E/42QSV140N8H15.5 kW heating14 kW cooling5,768 kWh/yr4$1,903
Midea UCMI140OB/DUCMI140IHB14.5 kW heating14 kW cooling5,658 kWh/yr4$1,867

Compare C-UV-140N8-QC3W / CDV-140HFN8-QC3W with another model

Mdv specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
4.20 kW
Rated heating capacity (7 Β°C)
14.50 kW
Heating power input
3.70 kW
EER, full load (tested)
3.32
COP, full load (tested)
3.87
Rated AEER
3.31
Rated ACOP
3.88
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
69.4 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mdv zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––6451,554
Coldresidential4.02.06814,983
Mixedcommercial––1,247806
Mixedresidential3.52.51,0911,860
Hotcommercial––3,369173
Hotresidential4.03.03,117272
Part-load test points (25 values)
c__t1_min_cap_power_rated
900 W
h__h1_min_cap_power_rated
565 W
h__h2_ext_cap_power_rated
5060 W
c__t1_half_cap_power_rated
1750 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1300 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2800 W
h__h2_ext_cap_heat_cap_rated
14130 W
h__h1_half_cap_heat_cap_rated
6550 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
535 W
c__t1_min_cap_cooling_cap_rated
3200 W
c__low_temp_full_cap_power_rated
3838.8 W
c__low_temp_half_cap_power_rated
1100 W
c__t1_half_cap_cooling_cap_rated
6500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3750 W
c__low_temp_full_cap_cooling_cap_rated
15078 W
c__low_temp_half_cap_cooling_cap_rated
7050 W

New Zealand E3 registration details

Registration number
AAC7211
GEMS registration id
151688
Status
approved, available (self-reported)
Registration expires
20 December 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.