c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
5,768 kWh
687 cooling + 5,081 heating
Estimated running cost
$1,903 / year
$159 / month Β· $19,034 over 10 years
Capacity
14 kW cooling
15.5 kW heating

15% less electricity than the median of 124 comparable 14 kW reverse cycle ducted split system registrations (6,763 kWh a year) in the cold zone. Uses less than 86% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 33% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air URC-140DS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,768$1,903$19,034
Mixed zone 2,996$989$9,887
Hot zone 3,403$1,123$11,230

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr2$1,483
Panasonic U-125PZ4R5 / S-125PE4*12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Panasonic U-125PZ4R8 / S-125PE4R12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling4,830 kWh/yr4$1,594

Heat pumps similar to the Actron Air URC-140DS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kaden KDI48 / KDI4814 kW heating14 kW cooling5,394 kWh/yr4$1,780
Midea DUCMI140IHB/UCMI140OB14.5 kW heating14 kW cooling5,596 kWh/yr4$1,847
Mdv C-UV-140N8-QC3W / CDV-140HFN8-QC3W14.5 kW heating14 kW cooling5,664 kWh/yr4$1,869
Carrier 38QSV140N8E/42QSV140N8H15.5 kW heating14 kW cooling5,768 kWh/yr4$1,903
Mdv C-UV-140N8-QC3W / CDV-140A6N8-QC3W14.5 kW heating14 kW cooling5,607 kWh/yr3.5$1,850
Rinnai DONSR15B1/DINLR15B114.5 kW heating14 kW cooling5,618 kWh/yr4$1,854
Midea UCMI140OB/DUCMI140IHB14.5 kW heating14 kW cooling5,658 kWh/yr4$1,867
Kaden KDI-14.015.5 kW heating14 kW cooling5,768 kWh/yr4$1,903

Compare URC-140DS / LRE-140DS with another model

Actron Air URC-140DS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
4.13 kW
Rated heating capacity (7 Β°C)
15.50 kW
Heating power input
3.82 kW
EER, full load (tested)
3.32
COP, full load (tested)
4.11
Rated AEER
3.36
Rated ACOP
4.02
Standby power (PIA)
9.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air URC-140DS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––8291,591
Coldresidential4.02.56875,081
Mixedcommercial––1,363828
Mixedresidential3.52.51,0941,902
Hotcommercial––3,523177
Hotresidential4.03.53,125278
Part-load test points (23 values)
c__t1_min_cap_power_rated
1100 W
h__h1_min_cap_power_rated
640 W
h__h2_ext_cap_power_rated
5350 W
c__t1_half_cap_power_rated
1860 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1440 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3300 W
h__h2_ext_cap_heat_cap_rated
15500 W
h__h1_half_cap_heat_cap_rated
7570 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
705 W
c__t1_min_cap_cooling_cap_rated
3450 W
c__low_temp_half_cap_power_rated
1170 W
c__t1_half_cap_cooling_cap_rated
7000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
4950 W
c__low_temp_half_cap_cooling_cap_rated
7500 W

New Zealand E3 registration details

Registration number
AAC8935
GEMS registration id
169894
Status
approved, available (self-reported)
Registration expires
29 May 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.