c/kWh
Energy rating (cooling)
5.5
Heating: 2.5
Annual electricity use
1,303 kWh
134 cooling + 1,169 heating
Estimated running cost
$430 / year
$36 / month Β· $4,300 over 10 years
Capacity
3.5 kW cooling
3.8 kW heating

7% less electricity than the median of 187 comparable 3.5 kW reverse cycle split system registrations (1,395 kWh a year) in the cold zone. Uses less than 73% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 84% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Aux ASW-H36A4 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,303$430$4,300
Mixed zone 645$213$2,129
Hot zone 646$213$2,132

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 3.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling1,144 kWh/yr5.5$378
Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling1,146 kWh/yr5.5$378
Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling1,183 kWh/yr6$390
Daikin RXV35AVMA / FTXV35AVMA3.7 kW heating3.5 kW cooling1,207 kWh/yr5$398
Hitachi RAC-VJ35PHAT/RAK-VJ35PHAT3.8 kW heating3.5 kW cooling1,209 kWh/yr5$399

Heat pumps similar to the Aux ASW-H36A4

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling1,144 kWh/yr5.5$378
Midea MFAG36VA-W/MFAG36VA-N3.8 kW heating3.5 kW cooling1,245 kWh/yr5.5$411
Kaden KSI124 kW heating3.5 kW cooling1,456 kWh/yr5$480
Kogan KASSSAC35TB3.6 kW heating3.5 kW cooling1,290 kWh/yr4.5$426
TCL TAC-13CHSD/XA72IG3.6 kW heating3.5 kW cooling1,290 kWh/yr4.5$426
TCL TAC-13CHSD/VEIH3.6 kW heating3.5 kW cooling1,287 kWh/yr4.5$425
Hyundai HYSSSAC35TD3.6 kW heating3.5 kW cooling1,287 kWh/yr4.5$425
Hyundai HYSSSAC35TC3.6 kW heating3.5 kW cooling1,287 kWh/yr4.5$425

Compare ASW-H36A4/CAR3DI with another model

Aux ASW-H36A4 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
3.55 kW
Cooling power input
0.79 kW
Rated heating capacity (7 Β°C)
3.80 kW
Heating power input
0.82 kW
EER, full load (tested)
4.30
COP, full load (tested)
4.72
Rated AEER
4.42
Rated ACOP
4.56
Standby power (PIA)
3.7 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
52.9 dB(A)
Outdoor sound power
60.2 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Aux ASW-H36A4 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––85384
Coldresidential5.52.51341,169
Mixedcommercial––340203
Mixedresidential5.03.0212433
Hotcommercial––51346
Hotresidential6.03.557670
Part-load test points (23 values)
c__t1_min_cap_power_rated
250 W
h__h1_min_cap_power_rated
220 W
h__h2_ext_cap_power_rated
1190 W
c__t1_half_cap_power_rated
390 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
310 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1100 W
h__h2_ext_cap_heat_cap_rated
3600 W
h__h1_half_cap_heat_cap_rated
1900 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
130 W
c__t1_min_cap_cooling_cap_rated
1530 W
c__low_temp_half_cap_power_rated
210 W
c__t1_half_cap_cooling_cap_rated
1830 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1180 W
c__low_temp_half_cap_cooling_cap_rated
1700 W

New Zealand E3 registration details

Registration number
AAC9890
GEMS registration id
175158
Status
approved, available (self-reported)
Registration expires
26 February 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8