c/kWh
Energy rating (cooling)
4.5
Heating: 2.5
Annual electricity use
1,290 kWh
149 cooling + 1,141 heating
Estimated running cost
$426 / year
$35 / month Β· $4,257 over 10 years
Capacity
3.5 kW cooling
3.6 kW heating

7% less electricity than the median of 187 comparable 3.5 kW reverse cycle split system registrations (1,395 kWh a year) in the cold zone. Uses less than 79% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 84% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

TCL TAC-13CHSD running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,290$426$4,257
Mixed zone 679$224$2,241
Hot zone 716$236$2,363

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 3.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling1,144 kWh/yr5.5$378
Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling1,146 kWh/yr5.5$378
Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling1,183 kWh/yr6$390
Daikin RXV35AVMA / FTXV35AVMA3.7 kW heating3.5 kW cooling1,207 kWh/yr5$398
Hitachi RAC-VJ35PHAT/RAK-VJ35PHAT3.8 kW heating3.5 kW cooling1,209 kWh/yr5$399

Heat pumps similar to the TCL TAC-13CHSD

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hyundai HYSSSAC35TD3.6 kW heating3.5 kW cooling1,287 kWh/yr4.5$425
Kogan KASSSAC35TB3.6 kW heating3.5 kW cooling1,290 kWh/yr4.5$426
Hyundai HYSSSAC35TB3.6 kW heating3.5 kW cooling1,287 kWh/yr4.5$425
Braemar TCHV03T1S/TSHV03T1S3.6 kW heating3.5 kW cooling1,296 kWh/yr4$428
TECO TWS-TSO35H3DVKT3.6 kW heating3.5 kW cooling1,306 kWh/yr4$431
Bonaire STH035S1AE/STH035S1AI3.6 kW heating3.5 kW cooling1,296 kWh/yr4$428
Kogan KASSSAC35TD3.6 kW heating3.5 kW cooling1,290 kWh/yr4.5$426
Gree GWH12AVDXD-K6DNA1A/O / GWH12AVDXD-K6DNA1A/I4 kW heating3.5 kW cooling1,303 kWh/yr5.5$430

Compare TAC-13CHSD/XA72IG with another model

TCL TAC-13CHSD specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
3.53 kW
Cooling power input
0.91 kW
Rated heating capacity (7 Β°C)
3.65 kW
Heating power input
0.87 kW
EER, full load (tested)
3.85
COP, full load (tested)
4.20
Rated AEER
3.86
Rated ACOP
4.14
Standby power (PIA)
3.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
56.9 dB(A)
Outdoor sound power
61.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

TCL TAC-13CHSD zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––38370
Coldresidential4.52.51491,141
Mixedcommercial––211199
Mixedresidential4.53.0237442
Hotcommercial––56944
Hotresidential5.53.564769
Part-load test points (18 values)
h__h2_ext_cap_power_rated
1151 W
c__t1_half_cap_power_rated
469 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
326 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
3840 W
h__h1_half_cap_heat_cap_rated
1780 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
245 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1870 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
1810 W

New Zealand E3 registration details

Registration number
AAC8837
GEMS registration id
169210
Status
approved, available (self-reported)
Registration expires
8 May 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.