c/kWh
Energy rating (cooling)
4.5
Heating: 2.5
Annual electricity use
1,290 kWh
149 cooling + 1,141 heating
Estimated running cost
$426 / year
$35 / month Β· $4,257 over 10 years
Capacity
3.5 kW cooling
3.6 kW heating

7% less electricity than the median of 187 comparable 3.5 kW reverse cycle split system registrations (1,395 kWh a year) in the cold zone. Uses less than 79% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 84% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kogan KASSSAC35TD running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,290$426$4,257
Mixed zone 679$224$2,241
Hot zone 716$236$2,363

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 3.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling1,144 kWh/yr5.5$378
Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling1,146 kWh/yr5.5$378
Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling1,183 kWh/yr6$390
Daikin RXV35AVMA / FTXV35AVMA3.7 kW heating3.5 kW cooling1,207 kWh/yr5$398
Hitachi RAC-VJ35PHAT/RAK-VJ35PHAT3.8 kW heating3.5 kW cooling1,209 kWh/yr5$399

Heat pumps similar to the Kogan KASSSAC35TD

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Braemar TCHV03T1S/TSHV03T1S3.6 kW heating3.5 kW cooling1,296 kWh/yr4$428
TECO TWS-TSO35H3DVKT3.6 kW heating3.5 kW cooling1,306 kWh/yr4$431
Hyundai HYSSSAC35TC3.6 kW heating3.5 kW cooling1,287 kWh/yr4.5$425
Bonaire STH035S1AE/STH035S1AI3.6 kW heating3.5 kW cooling1,296 kWh/yr4$428
TCL TAC-13CHSD/VEIH3.6 kW heating3.5 kW cooling1,287 kWh/yr4.5$425
Hyundai HYSSSAC35TD3.6 kW heating3.5 kW cooling1,287 kWh/yr4.5$425
TCL TAC-13CHSD/XA72IG3.6 kW heating3.5 kW cooling1,290 kWh/yr4.5$426
Gree GWH12AVDXD-K6DNA1A/O / GWH12AVDXD-K6DNA1A/I4 kW heating3.5 kW cooling1,303 kWh/yr5.5$430

Compare KASSSAC35TD with another model

Kogan KASSSAC35TD specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
3.53 kW
Cooling power input
0.91 kW
Rated heating capacity (7 Β°C)
3.65 kW
Heating power input
0.87 kW
EER, full load (tested)
3.85
COP, full load (tested)
4.20
Rated AEER
3.86
Rated ACOP
4.14
Standby power (PIA)
3.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
56.9 dB(A)
Outdoor sound power
61.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kogan KASSSAC35TD zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––38370
Coldresidential4.52.51491,141
Mixedcommercial––211199
Mixedresidential4.53.0237442
Hotcommercial––56944
Hotresidential5.53.564769
Part-load test points (18 values)
h__h2_ext_cap_power_rated
1151 W
c__t1_half_cap_power_rated
469 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
326 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
3840 W
h__h1_half_cap_heat_cap_rated
1780 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
245 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1870 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
1810 W

Other model numbers on registration AAC8806

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC8806
GEMS registration id
169002
Status
approved, available (self-reported)
Registration expires
27 April 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
KASSSAC35T*
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 26 September 2026; last checked 27 September 2026. How the derived figures are calculated.