c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
2,046 kWh
268 cooling + 1,778 heating
Estimated running cost
$675 / year
$56 / month Β· $6,752 over 10 years
Capacity
5.2 kW cooling
5.2 kW heating

5% less electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 74% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 76% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Bonaire CRC6911050 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,046$675$6,752
Mixed zone 1,096$362$3,617
Hot zone 1,309$432$4,320

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5.2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606
Gree GWH15QDXE-K6DNA1A/O / GWH15QDXE-K6DNA1A/I4.7 kW heating4.6 kW cooling1,839 kWh/yr3$607
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608

Heat pumps similar to the Bonaire CRC6911050

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
TCL TAC-18CHSD/TPH11IT5.2 kW heating5.2 kW cooling2,046 kWh/yr3.5$675
Braemar TCHV50T1S/TSHV50T1S5.2 kW heating5.2 kW cooling2,046 kWh/yr3.5$675
Gree GWH18QEXF-K6DNC8A/O / GWH18QEXF-K6DNC8A/I5.6 kW heating5.2 kW cooling2,042 kWh/yr4.5$674
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608
Akai AK-TP525.2 kW heating5.2 kW cooling2,046 kWh/yr3.5$675
Gree GWH18QEXF-K6DNC8A/O / GWH18QEXF-K6DNA1A/I5.6 kW heating5.2 kW cooling2,042 kWh/yr4.5$674
Ers Tech ERS-AC52F015.2 kW heating5.2 kW cooling2,046 kWh/yr3.5$675
Aux ASW-H52A4/CAR3DI5.2 kW heating5.2 kW cooling2,056 kWh/yr5$678

Compare CRC6911050/CRC6911150 with another model

Bonaire CRC6911050 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.20 kW
Cooling power input
1.40 kW
Rated heating capacity (7 Β°C)
5.20 kW
Heating power input
1.20 kW
EER, full load (tested)
3.60
COP, full load (tested)
4.20
Rated AEER
3.67
Rated ACOP
4.27
Standby power (PIA)
5.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
49.4 dB(A)
Outdoor sound power
62 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Bonaire CRC6911050 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––424575
Coldresidential3.52.02681,778
Mixedcommercial––616304
Mixedresidential3.52.5422674
Hotcommercial––1,46068
Hotresidential4.03.01,203106
Part-load test points (18 values)
c__t1_half_cap_power_rated
560 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
510 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
1810 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
2600 W
h__h2_full_cap_heat_cap_rated
5300 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
1279.6000000000001 W
c__low_temp_half_cap_power_rated
400 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
2500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
5600.4 W
c__low_temp_half_cap_cooling_cap_rated
2600 W

New Zealand E3 registration details

Registration number
AAC8186
GEMS registration id
160939
Status
approved, available (self-reported)
Registration expires
22 April 2029
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9