c/kWh
Energy rating (cooling)
4.5
Heating: 2.5
Annual electricity use
1,841 kWh
239 cooling + 1,602 heating
Estimated running cost
$608 / year
$51 / month Β· $6,075 over 10 years
Capacity
5.2 kW cooling
5.2 kW heating

14% less electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 95% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 78% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Midea MFCA50VA-W running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,841$608$6,075
Mixed zone 1,002$331$3,307
Hot zone 1,195$394$3,944

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5.2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518

Heat pumps similar to the Midea MFCA50VA-W

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Bonaire CRC6911050/CRC69111505.2 kW heating5.2 kW cooling2,046 kWh/yr3.5$675
Ers Tech ERS-AC52F015.2 kW heating5.2 kW cooling2,046 kWh/yr3.5$675
Aux ASW-H52A4/CAR3DI5.2 kW heating5.2 kW cooling2,056 kWh/yr5$678
Gree GWH18QEXF-K6DNC8A/O / GWH18QEXF-K6DN**A/I5.6 kW heating5.2 kW cooling2,042 kWh/yr4.5$674
TCL TAC-18CHSD/TPH11IT5.2 kW heating5.2 kW cooling2,046 kWh/yr3.5$675
Gree GWH18QEXF-K6DNC8A/O / GWH18QEXF-K6DNC8A/I5.6 kW heating5.2 kW cooling2,042 kWh/yr4.5$674
Braemar TCHV50T1S/TSHV50T1S5.2 kW heating5.2 kW cooling2,046 kWh/yr3.5$675
Akai AK-TP525.2 kW heating5.2 kW cooling2,046 kWh/yr3.5$675

Compare MFCA50VA-W/MFCA50VA-N with another model

Midea MFCA50VA-W specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.20 kW
Cooling power input
1.36 kW
Rated heating capacity (7 Β°C)
5.20 kW
Heating power input
1.24 kW
EER, full load (tested)
3.93
COP, full load (tested)
4.23
Rated AEER
3.81
Rated ACOP
4.17
Standby power (PIA)
1.4 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
61.4 dB(A)
Outdoor sound power
65.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Midea MFCA50VA-W zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––320516
Coldresidential4.52.52391,602
Mixedcommercial––524277
Mixedresidential4.03.0382620
Hotcommercial––1,27457
Hotresidential4.53.51,10590
Part-load test points (25 values)
c__t1_min_cap_power_rated
578 W
h__h1_min_cap_power_rated
430 W
h__h2_ext_cap_power_rated
2470 W
c__t1_half_cap_power_rated
610 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
490 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2320 W
h__h2_ext_cap_heat_cap_rated
7030 W
h__h1_half_cap_heat_cap_rated
2670 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
380 W
c__t1_min_cap_cooling_cap_rated
2655 W
c__low_temp_full_cap_power_rated
1243.04 W
c__low_temp_half_cap_power_rated
390 W
c__t1_half_cap_cooling_cap_rated
2830 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2600 W
c__low_temp_full_cap_cooling_cap_rated
5600.4 W
c__low_temp_half_cap_cooling_cap_rated
2720 W

New Zealand E3 registration details

Registration number
AAC7448
GEMS registration id
153905
Status
approved, available (self-reported)
Registration expires
25 April 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.