c/kWh
Energy rating (cooling)
2.5
Heating: 1.5
Annual electricity use
5,580 kWh
644 cooling + 4,936 heating
Estimated running cost
$1,841 / year
$153 / month Β· $18,414 over 10 years
Capacity
10 kW cooling
11.5 kW heating

17% more electricity than the median of 136 comparable 10 kW reverse cycle ducted split system registrations (4,758 kWh a year) in the cold zone. Uses less than 14% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 35% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Bonaire CRC6960010 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,580$1,841$18,414
Mixed zone 2,788$920$9,200
Hot zone 3,203$1,057$10,570

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Panasonic U-100PZ3R5 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,660 kWh/yr4$1,208
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,687 kWh/yr3.5$1,217
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling3,713 kWh/yr5$1,225

Heat pumps similar to the Bonaire CRC6960010

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Pioneer International VPC-36A110 kW heating10 kW cooling4,523 kWh/yr3.5$1,493
Mitsubishi Electric PUZ-ZM100VKA2-A/PEA-M100HAA2-UF11.2 kW heating10 kW cooling4,393 kWh/yr2.5$1,450
Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling4,227 kWh/yr4.5$1,395
Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling3,866 kWh/yr2.5$1,276
Panasonic U-100PZ4R8 / S-100PE4R10 kW heating10 kW cooling3,866 kWh/yr2.5$1,276
Daikin RZAV100FV1 / FBA100BVMA12 kW heating10 kW cooling4,302 kWh/yr3.5$1,420
Mitsubishi Electric PUZ-ZM100VKA-A/PEA-M100HAA11.2 kW heating10 kW cooling4,393 kWh/yr2.5$1,450
Daikin RZAV100CV1 / FBA100BVMA11.2 kW heating10 kW cooling4,295 kWh/yr3$1,417

Compare CRC6960010/CRC6960110 with another model

Bonaire CRC6960010 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
3.12 kW
Rated heating capacity (7 Β°C)
11.50 kW
Heating power input
3.19 kW
EER, full load (tested)
3.36
COP, full load (tested)
4.04
Rated AEER
3.17
Rated ACOP
3.57
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Bonaire CRC6960010 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,3941,586
Coldresidential2.51.56444,936
Mixedcommercial––1,760784
Mixedresidential2.52.01,0111,777
Hotcommercial––3,930169
Hotresidential2.52.52,941262
Part-load test points (20 values)
h__h2_ext_cap_power_rated
3200 W
c__t1_half_cap_power_rated
1100 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1300 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
8400 W
h__h1_half_cap_heat_cap_rated
5750 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
2851.6800000000003 W
c__low_temp_half_cap_power_rated
1005.4000000000001 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5000 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
10770 W
c__low_temp_half_cap_cooling_cap_rated
5385 W

New Zealand E3 registration details

Registration number
AAC6613
GEMS registration id
145989
Status
approved, available (self-reported)
Registration expires
20 April 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: haier.com/cn. How the derived figures are calculated.