c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
4,890 kWh
579 cooling + 4,311 heating
Estimated running cost
$1,614 / year
$134 / month Β· $16,137 over 10 years
Capacity
10 kW cooling
12 kW heating

3% more electricity than the median of 135 comparable 10 kW reverse cycle ducted split system registrations (4,767 kWh a year) in the cold zone. Uses less than 41% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 40% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Braemar KCHB100D1B running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,890$1,614$16,137
Mixed zone 2,429$802$8,016
Hot zone 2,918$963$9,629

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Panasonic U-100PZ3R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,660 kWh/yr4$1,208
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,687 kWh/yr3.5$1,217
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling3,713 kWh/yr5$1,225

Heat pumps similar to the Braemar KCHB100D1B

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R8 / S-100PE4R10 kW heating10 kW cooling3,866 kWh/yr2.5$1,276
Mitsubishi Electric PUZ-ZM100VKA2-A/PEA-M100HAA211.2 kW heating10 kW cooling4,393 kWh/yr2.5$1,450
Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling4,227 kWh/yr4.5$1,395
Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling3,866 kWh/yr2.5$1,276
Daikin RZAV100FV1 / FBA100BVMA12 kW heating10 kW cooling4,302 kWh/yr3.5$1,420
Mitsubishi Electric PUZ-ZM100VKA2-A/PEA-M100HAA2-UF11.2 kW heating10 kW cooling4,393 kWh/yr2.5$1,450
Pioneer International VPC-36A1/CPE-36A110 kW heating10 kW cooling4,523 kWh/yr3.5$1,493
Daikin RZAV100CV1 / FBA100BVMA11.2 kW heating10 kW cooling4,295 kWh/yr3$1,417

Compare KCHB100D1B/KDHB100D1S with another model

Braemar KCHB100D1B specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
12.00 kW
Heating power input
–
EER, full load (tested)
3.35
COP, full load (tested)
3.81
Rated AEER
3.15
Rated ACOP
3.72
Standby power (PIA)
8.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
72.2 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Braemar KCHB100D1B zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,0131,308
Coldresidential3.02.05794,311
Mixedcommercial––1,377654
Mixedresidential3.02.59101,519
Hotcommercial––3,502137
Hotresidential3.03.52,705213
Part-load test points (21 values)
c__t1_min_cap_power_rated
900 W
h__h1_min_cap_power_rated
700 W
h__h2_ext_cap_power_rated
3300 W
c__t1_half_cap_power_rated
1060 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1100 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3800 W
h__h2_ext_cap_heat_cap_rated
9500 W
h__h1_half_cap_heat_cap_rated
6000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
665 W
c__t1_min_cap_cooling_cap_rated
4400 W
c__t1_half_cap_cooling_cap_rated
5000 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
4500 W

New Zealand E3 registration details

Registration number
AAC10070
GEMS registration id
–
Status
approved
Registration expires
19 April 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.