c/kWh
Energy rating (cooling)
3
Heating: 1
Annual electricity use
6,244 kWh
596 cooling + 5,648 heating
Estimated running cost
$2,061 / year
$172 / month Β· $20,605 over 10 years
Capacity
10.2 kW cooling
12.1 kW heating

40% more electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 0% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 29% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Braemar KCHV100D1B running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,244$2,061$20,605
Mixed zone 2,963$978$9,778
Hot zone 3,033$1,001$10,009

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10.2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr2.5$354
Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Panasonic U-100PZ3R5 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Kogan KASSSAC90HA9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210
Kogan KASSSAC90HB9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210

Heat pumps similar to the Braemar KCHV100D1B

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hisense AUW-100U4RK1/ AUC-100UR4RKC111 kW heating10.2 kW cooling5,432 kWh/yr2.5$1,793
Daikin RZAV100FY1 / FCA100CVMA12 kW heating10 kW cooling3,792 kWh/yr4$1,251
Midea UCMI105OC/CASMI105IC10.5 kW heating10 kW cooling4,000 kWh/yr3.5$1,320
Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Fujitsu AOTG36KBTA/AUTG36KRLA11.2 kW heating10 kW cooling4,244 kWh/yr3$1,401
Panasonic U-100PZ3R5 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Actron Air URC-100DS / CRE-100DS10.5 kW heating10 kW cooling4,000 kWh/yr3.5$1,320
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr2.5$354

Compare KCHV100D1B/KBHV100D1S with another model

Braemar KCHV100D1B specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
10.20 kW
Cooling power input
3.04 kW
Rated heating capacity (7 Β°C)
12.10 kW
Heating power input
3.40 kW
EER, full load (tested)
3.34
COP, full load (tested)
3.56
Rated AEER
3.34
Rated ACOP
3.54
Standby power (PIA)
4.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
59.2 dB(A)
Outdoor sound power
70.6 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Braemar KCHV100D1B zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,1531,579
Coldresidential3.01.05965,648
Mixedcommercial––1,512777
Mixedresidential3.01.59332,030
Hotcommercial––3,696141
Hotresidential3.03.02,802231
Part-load test points (23 values)
c__t1_min_cap_power_rated
600 W
h__h1_min_cap_power_rated
520 W
c__t1_half_cap_power_rated
1000 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1150 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
2850 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2600 W
h__h1_half_cap_heat_cap_rated
5600 W
h__h2_full_cap_heat_cap_rated
7400 W
h__h2_is_capable_extended_load
No
c__low_temp_min_cap_power_rated
480 W
c__t1_min_cap_cooling_cap_rated
2890 W
c__low_temp_full_cap_power_rated
2778.56 W
c__low_temp_half_cap_power_rated
914 W
c__t1_half_cap_cooling_cap_rated
4650 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
3000 W
c__low_temp_full_cap_cooling_cap_rated
10985.4 W
c__low_temp_half_cap_cooling_cap_rated
5008.05 W

1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
KCHV100D1B/KBHV100D1SAAC700436,153

New Zealand E3 registration details

Registration number
AAC6499
GEMS registration id
143047
Status
approved, available (self-reported)
Registration expires
24 February 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: gree.com. How the derived figures are calculated.