New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, cassette
Hisense AUW-100U4RK1/ AUC-100UR4RKC1 Heat Pump
Hisense AUW-100U4RK1/ AUC-100UR4RKC1 is a 10.2 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7511).
- Energy rating (cooling)
- 2.5
- Heating: 1.5
- Annual electricity use
- 5,432 kWh
- 645 cooling + 4,787 heating
- Estimated running cost
- $1,793 / year
- $149 / month Β· $17,926 over 10 years
- Capacity
- 10.2 kW cooling
- 11 kW heating
22% more electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 5% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 35% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Hisense AUW-100U4RK1 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 5,432 | $1,793 | $17,926 |
| Mixed zone | 2,682 | $885 | $8,851 |
| Hot zone | 3,194 | $1,054 | $10,540 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 10.2 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr | 2.5 | $354 | |
| Panasonic U-100PZ3R5 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Kogan KASSSAC90HD9.5 kW heating9 kW cooling3,668 kWh/yr | 3.5 | $1,210 | |
| Kogan KASSSAC90HF9.5 kW heating9 kW cooling3,668 kWh/yr | 3.5 | $1,210 |
Heat pumps similar to the Hisense AUW-100U4RK1
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Braemar KCHV100D1B/KBHV100D1S12.1 kW heating10.2 kW cooling6,244 kWh/yr | 3 | $2,061 | |
| Braemar KCHV100D1B/KBHV100D1S12 kW heating10.1 kW cooling6,153 kWh/yr | 3 | $2,030 | |
| Panasonic U-100PZ3R5 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Actron Air URC-100DS / CRE-100DS10.5 kW heating10 kW cooling4,000 kWh/yr | 3.5 | $1,320 | |
| Midea UCMI105OC/CASMI105IC10.5 kW heating10 kW cooling4,000 kWh/yr | 3.5 | $1,320 | |
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr | 2.5 | $354 | |
| Daikin RZAV100FY1 / FCA100CVMA12 kW heating10 kW cooling3,792 kWh/yr | 4 | $1,251 | |
| Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 |
Compare AUW-100U4RK1/ AUC-100UR4RKC1 with another model
Hisense AUW-100U4RK1 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Cassette
- Rated cooling capacity (35 Β°C)
- 10.20 kW
- Cooling power input
- 3.09 kW
- Rated heating capacity (7 Β°C)
- 11.00 kW
- Heating power input
- 3.06 kW
- EER, full load (tested)
- 3.36
- COP, full load (tested)
- 3.78
- Rated AEER
- 3.28
- Rated ACOP
- 3.58
- Standby power (PIA)
- 5.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Hisense AUW-100U4RK1 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,428 | 1,452 |
| Coldresidential | residential | 2.5 | 1.5 | 645 | 4,787 |
| Mixedcommercial | commercial | β | β | 1,800 | 678 |
| Mixedresidential | residential | 2.5 | 2.0 | 1,013 | 1,669 |
| Hotcommercial | commercial | β | β | 4,017 | 130 |
| Hotresidential | residential | 2.5 | 3.0 | 2,989 | 205 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 2650 W
- c__t1_half_cap_power_rated
- 1150 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1050 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 7500 W
- h__h1_half_cap_heat_cap_rated
- 5500 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 2824.26 W
- c__low_temp_half_cap_power_rated
- 1051.1000000000001 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 5100 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 10985.4 W
- c__low_temp_half_cap_cooling_cap_rated
- 5492.7 W
New Zealand E3 registration details
- Registration number
- AAC7511
- GEMS registration id
- 154297
- Status
- approved, available (self-reported)
- Registration expires
- 16 May 2028
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.