c/kWh
Energy rating (cooling)
2
Heating: 2.5
Annual electricity use
3,256 kWh
506 cooling + 2,750 heating
Estimated running cost
$1,074 / year
$90 / month Β· $10,745 over 10 years
Capacity
7.3 kW cooling
8.5 kW heating

About the same electricity as the median of 10 comparable 7 kW reverse cycle fixed registrations (3,247 kWh a year) in the cold zone. Uses less than 40% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 58% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Braemar NCHV72D13 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,256$1,074$10,745
Mixed zone 1,810$597$5,973
Hot zone 2,367$781$7,811

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.3 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Haier 4U71S2PR1FA7.1 kW heating7.1 kW cooling2,634 kWh/yr3$869
Rinnai MON3H07B1LA7.3 kW heating7.2 kW cooling2,662 kWh/yr3.5$878
Actron Air MRC-071AS-37.8 kW heating7.1 kW cooling3,067 kWh/yr3$1,012
Haier 4U80S2PR1FA8 kW heating8 kW cooling3,093 kWh/yr3.5$1,021

Heat pumps similar to the Braemar NCHV72D13

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai MON3H07B1LA7.3 kW heating7.2 kW cooling2,662 kWh/yr3.5$878
Haier 4U71S2PR1FA8 kW heating7.1 kW cooling3,337 kWh/yr2$1,101
Actron Air MRC-071AS-37.8 kW heating7.1 kW cooling3,067 kWh/yr3$1,012
Haier 4U71S2PR1FA7.1 kW heating7.1 kW cooling2,634 kWh/yr3$869
Hitachi RAM-G70N4HCE8.5 kW heating7 kW cooling3,198 kWh/yr4.5$1,055
Daikin 4MXM68R2VMA8.6 kW heating6.8 kW cooling3,649 kWh/yr3.5$1,204

Other Braemar models of similar capacity

ModelStarsEst. cost / yrCompare
Braemar NCHV07D13B8.3 kW heating7.3 kW cooling3,237 kWh/yr3$1,068
Braemar NCHV72D138.6 kW heating7.2 kW cooling3,278 kWh/yr2$1,082

Compare NCHV72D13 with another model

Braemar NCHV72D13 specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.30 kW
Cooling power input
2.00 kW
Rated heating capacity (7 Β°C)
8.50 kW
Heating power input
1.90 kW
EER, full load (tested)
3.72
COP, full load (tested)
4.50
Rated AEER
3.57
Rated ACOP
4.37
Standby power (PIA)
13.7 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
57.6 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Braemar NCHV72D13 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,099894
Coldresidential2.02.55062,750
Mixedcommercial––1,363476
Mixedresidential2.03.07691,041
Hotcommercial––2,955117
Hotresidential2.53.52,191176
Part-load test points (20 values)
h__h2_ext_cap_power_rated
2500 W
c__t1_half_cap_power_rated
830 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
720 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
7900 W
h__h1_half_cap_heat_cap_rated
3900 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
1828 W
c__low_temp_half_cap_power_rated
758.62 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3400 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
7862.099999999999 W
c__low_temp_half_cap_cooling_cap_rated
3661.7999999999997 W

1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
NCHV72D13AAC665723,278

New Zealand E3 registration details

Registration number
AAC7568
GEMS registration id
154222
Status
approved, available (self-reported)
Registration expires
13 June 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 19

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: gree.com. How the derived figures are calculated.