c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
3,653 kWh
449 cooling + 3,204 heating
Estimated running cost
$1,205 / year
$100 / month Β· $12,055 over 10 years
Capacity
8.7 kW cooling
9.3 kW heating

15% less electricity than the median of 35 comparable 8 kW reverse cycle ducted split system registrations (4,295 kWh a year) in the cold zone. Uses less than 94% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 51% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Carrier 38QSM090D8S running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,653$1,205$12,055
Mixed zone 1,923$635$6,346
Hot zone 2,164$714$7,141

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 8.7 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Carrier 38QSM080D8S/42QSM080D8S8.3 kW heating7.8 kW cooling3,471 kWh/yr3.5$1,145

Heat pumps similar to the Carrier 38QSM090D8S

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
LG UU85WR3 U40/UHN85B7 N709.4 kW heating8.8 kW cooling4,201 kWh/yr2.5$1,386
LG UU85WR2 U40/UHN85B7 N709.4 kW heating8.8 kW cooling4,953 kWh/yr1.5$1,634
TCL TCD85D1HWH-DVO/TCD85D1HWH-DVI10 kW heating8.5 kW cooling3,969 kWh/yr3$1,310
Fujitsu AOTH30KCTA/ARTH30KHTA10 kW heating8.5 kW cooling3,774 kWh/yr3$1,245
Daikin RZAV85CV1 / FBA85BVMA10 kW heating8.5 kW cooling3,930 kWh/yr2.5$1,297
Temperzone OSAT 85RLSFH / ISDT 85LY10 kW heating8.5 kW cooling4,388 kWh/yr3$1,448
Daikin RZAV85CY1 / FBA85BVMA10 kW heating8.5 kW cooling3,930 kWh/yr2.5$1,297
Fujitsu AOTH30KCTA/ARTH30KMTAP10 kW heating8.5 kW cooling3,854 kWh/yr3$1,272

Compare 38QSM090D8S/42QSM090D8S with another model

Carrier 38QSM090D8S specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
8.70 kW
Cooling power input
2.65 kW
Rated heating capacity (7 Β°C)
9.28 kW
Heating power input
2.32 kW
EER, full load (tested)
3.59
COP, full load (tested)
4.45
Rated AEER
3.24
Rated ACOP
3.93
Standby power (PIA)
11.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Carrier 38QSM090D8S zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––7,0791,023
Coldresidential3.52.04493,204
Mixedcommercial––1,826544
Mixedresidential3.52.57011,222
Hotcommercial––2,231126
Hotresidential4.03.01,971193
Part-load test points (23 values)
c__t1_min_cap_power_rated
770 W
h__h1_min_cap_power_rated
500 W
h__h2_ext_cap_power_rated
3660 W
c__t1_half_cap_power_rated
1260 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
970 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2430 W
h__h2_ext_cap_heat_cap_rated
9700 W
h__h1_half_cap_heat_cap_rated
4660 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
390 W
c__t1_min_cap_cooling_cap_rated
2950 W
c__low_temp_half_cap_power_rated
780 W
c__t1_half_cap_cooling_cap_rated
4400 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2520 W
c__low_temp_half_cap_cooling_cap_rated
4600 W

New Zealand E3 registration details

Registration number
AAC10175
GEMS registration id
179576
Status
approved, available (self-reported)
Registration expires
5 August 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: midea.com.cn. How the derived figures are calculated.