c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
3,471 kWh
400 cooling + 3,071 heating
Estimated running cost
$1,145 / year
$95 / month Β· $11,454 over 10 years
Capacity
7.8 kW cooling
8.3 kW heating

19% less electricity than the median of 35 comparable 8 kW reverse cycle ducted split system registrations (4,295 kWh a year) in the cold zone. Uses less than 97% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 54% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Carrier 38QSM080D8S running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,471$1,145$11,454
Mixed zone 1,757$580$5,798
Hot zone 1,953$644$6,445

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,720 kWh/yr3.5$898
Aurora AU-BS24HR-2A-O / AU-LCF24-2A-I7.5 kW heating7.3 kW cooling2,720 kWh/yr3.5$898
Mdv C-UV-74N8-QC3W / CDV-74A6N8-QC3W7.5 kW heating7.4 kW cooling2,744 kWh/yr3.5$906
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,756 kWh/yr3$909
TCL TCD71D1HWH-DVO/TCD71D1HWH-DVI7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914

Heat pumps similar to the Carrier 38QSM080D8S

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
LG UU85WR3 U40/UMN85M1 N109 kW heating8 kW cooling4,467 kWh/yr2.5$1,474
LG UU85WR2 U40/UMN85M1 N109 kW heating8 kW cooling5,238 kWh/yr1.5$1,729
Mdv C-UV-74N8-QC3W / CDV-74A6N8-QC3W7.5 kW heating7.4 kW cooling2,744 kWh/yr3.5$906
Actron Air LRC-071DS / LRE-071DS7.5 kW heating7.3 kW cooling2,771 kWh/yr4$914
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,720 kWh/yr3.5$898
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,756 kWh/yr3$909
Aurora AU-BS24HR-2A-O / AU-LCF24-2A-I7.5 kW heating7.3 kW cooling2,720 kWh/yr3.5$898
Midea UCMI70OC/DUCMI70IC7.5 kW heating7.3 kW cooling2,771 kWh/yr4$914

Compare 38QSM080D8S/42QSM080D8S with another model

Carrier 38QSM080D8S specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.85 kW
Cooling power input
2.50 kW
Rated heating capacity (7 Β°C)
8.25 kW
Heating power input
2.30 kW
EER, full load (tested)
3.31
COP, full load (tested)
4.08
Rated AEER
3.12
Rated ACOP
3.56
Standby power (PIA)
5.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Carrier 38QSM080D8S zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,401954
Coldresidential3.52.04003,071
Mixedcommercial––1,728490
Mixedresidential3.52.56281,129
Hotcommercial––2,450103
Hotresidential4.03.01,791162
Part-load test points (23 values)
c__t1_min_cap_power_rated
580 W
h__h1_min_cap_power_rated
380 W
h__h2_ext_cap_power_rated
2830 W
c__t1_half_cap_power_rated
1320 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
880 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1760 W
h__h2_ext_cap_heat_cap_rated
7480 W
h__h1_half_cap_heat_cap_rated
4200 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
290 W
c__t1_min_cap_cooling_cap_rated
2650 W
c__low_temp_half_cap_power_rated
750 W
c__t1_half_cap_cooling_cap_rated
4020 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2080 W
c__low_temp_half_cap_cooling_cap_rated
4000 W

New Zealand E3 registration details

Registration number
AAC10173
GEMS registration id
179572
Status
approved, available (self-reported)
Registration expires
27 July 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: midea.com.cn. How the derived figures are calculated.