c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
2,771 kWh
341 cooling + 2,430 heating
Estimated running cost
$914 / year
$76 / month Β· $9,144 over 10 years
Capacity
7.3 kW cooling
7.5 kW heating

15% less electricity than the median of 80 comparable 7 kW reverse cycle ducted split system registrations (3,279 kWh a year) in the cold zone. Uses less than 83% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 65% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air LRC-071DS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,771$914$9,144
Mixed zone 1,464$483$4,831
Hot zone 1,695$559$5,594

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.3 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ4R5 / S-6071PF3E6.8 kW heating6.8 kW cooling2,674 kWh/yr3$882

Heat pumps similar to the Actron Air LRC-071DS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Aurora AU-BS24HR-2A-O / AU-LCF24-2A-I7.5 kW heating7.3 kW cooling2,720 kWh/yr3.5$898
Kaden KDI24 / KDI247.5 kW heating7.3 kW cooling2,846 kWh/yr4$939
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,720 kWh/yr3.5$898
Midea UCMI70OB/DUCMI70IB7.4 kW heating7.3 kW cooling2,828 kWh/yr4$933
Kaden KDI-7.07.5 kW heating7.3 kW cooling2,773 kWh/yr4$915
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,756 kWh/yr3$909
Carrier 38QSP070N8/42QSP070N87.5 kW heating7.3 kW cooling2,771 kWh/yr4$914
Midea UCMI70OC/DUCMI70IC7.5 kW heating7.3 kW cooling2,771 kWh/yr4$914

Compare LRC-071DS / LRE-071DS with another model

Actron Air LRC-071DS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.30 kW
Cooling power input
2.14 kW
Rated heating capacity (7 Β°C)
7.50 kW
Heating power input
1.84 kW
EER, full load (tested)
3.37
COP, full load (tested)
4.00
Rated AEER
3.39
Rated ACOP
4.04
Standby power (PIA)
4.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air LRC-071DS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––380763
Coldresidential4.02.53412,430
Mixedcommercial––657399
Mixedresidential4.03.0548916
Hotcommercial––1,67885
Hotresidential4.53.51,563132
Part-load test points (23 values)
c__t1_min_cap_power_rated
410 W
h__h1_min_cap_power_rated
431 W
h__h2_ext_cap_power_rated
2740 W
c__t1_half_cap_power_rated
935 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
743 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2325 W
h__h2_ext_cap_heat_cap_rated
7850 W
h__h1_half_cap_heat_cap_rated
3837 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
265 W
c__t1_min_cap_cooling_cap_rated
850 W
c__low_temp_half_cap_power_rated
556 W
c__t1_half_cap_cooling_cap_rated
3500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1900 W
c__low_temp_half_cap_cooling_cap_rated
3650 W

New Zealand E3 registration details

Registration number
AAC8933
GEMS registration id
169642
Status
approved, available (self-reported)
Registration expires
29 May 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.