New Zealand Β· costs in NZD
Reverse cycle split system air conditioner
Kaden KDI24 / KDI24 Heat Pump
Kaden KDI24 / KDI24 is a 7.3 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7191).
- Energy rating (cooling)
- 4
- Heating: 2
- Annual electricity use
- 2,846 kWh
- 339 cooling + 2,507 heating
- Estimated running cost
- $939 / year
- $78 / month Β· $9,392 over 10 years
- Capacity
- 7.3 kW cooling
- 7.5 kW heating
13% less electricity than the median of 80 comparable 7 kW reverse cycle ducted split system registrations (3,279 kWh a year) in the cold zone. Uses less than 76% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 64% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Kaden KDI24 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,846 | $939 | $9,392 |
| Mixed zone | 1,479 | $488 | $4,881 |
| Hot zone | 1,578 | $521 | $5,207 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 7.3 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-71PZ4R5 / S-6071PF3E6.8 kW heating6.8 kW cooling2,674 kWh/yr | 3 | $882 | |
| Aurora AU-BS24HR-2A-O / AU-LCF24-2A-I7.5 kW heating7.3 kW cooling2,720 kWh/yr | 3.5 | $898 | |
| Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,720 kWh/yr | 3.5 | $898 | |
| Mdv C-UV-74N8-QC3W / CDV-74A6N8-QC3W7.5 kW heating7.4 kW cooling2,744 kWh/yr | 3.5 | $906 | |
| Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,756 kWh/yr | 3 | $909 |
Heat pumps similar to the Kaden KDI24
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Actron Air LRC-071CS / LRE-071CS7.7 kW heating7.3 kW cooling2,793 kWh/yr | 3.5 | $922 | |
| Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,756 kWh/yr | 3 | $909 | |
| Carrier 38QSP070N8/42QSP070N87.5 kW heating7.3 kW cooling2,771 kWh/yr | 4 | $914 | |
| Actron Air LRC-071DS / LRE-071DS7.5 kW heating7.3 kW cooling2,771 kWh/yr | 4 | $914 | |
| Aurora AU-BS24HR-2A-O / AU-LCF24-2A-I7.5 kW heating7.3 kW cooling2,720 kWh/yr | 3.5 | $898 | |
| Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,720 kWh/yr | 3.5 | $898 | |
| Midea UCMI70OC/DUCMI70IC7.5 kW heating7.3 kW cooling2,771 kWh/yr | 4 | $914 | |
| Midea UCMI70OB/DUCMI70IB7.4 kW heating7.3 kW cooling2,828 kWh/yr | 4 | $933 |
Compare KDI24 / KDI24 with another model
Kaden KDI24 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 7.30 kW
- Cooling power input
- 2.10 kW
- Rated heating capacity (7 Β°C)
- 7.50 kW
- Heating power input
- 1.80 kW
- EER, full load (tested)
- 3.54
- COP, full load (tested)
- 4.22
- Rated AEER
- 3.42
- Rated ACOP
- 4.09
- Standby power (PIA)
- 10.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 65 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Kaden KDI24 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 864 | 801 |
| Coldresidential | residential | 4.0 | 2.0 | 339 | 2,507 |
| Mixedcommercial | commercial | β | β | 783 | 425 |
| Mixedresidential | residential | 4.0 | 2.5 | 528 | 951 |
| Hotcommercial | commercial | β | β | 1,830 | 100 |
| Hotresidential | residential | 5.0 | 3.0 | 1,426 | 152 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 540 W
- h__h1_min_cap_power_rated
- 360 W
- h__h2_ext_cap_power_rated
- 2680 W
- c__t1_half_cap_power_rated
- 1070 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 710 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 1790 W
- h__h2_ext_cap_heat_cap_rated
- 7520 W
- h__h1_half_cap_heat_cap_rated
- 3610 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 260 W
- c__t1_min_cap_cooling_cap_rated
- 2380 W
- c__low_temp_full_cap_power_rated
- 1919.4 W
- c__low_temp_half_cap_power_rated
- 595 W
- c__t1_half_cap_cooling_cap_rated
- 3500 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 1845 W
- c__low_temp_full_cap_cooling_cap_rated
- 7862.099999999999 W
- c__low_temp_half_cap_cooling_cap_rated
- 3500 W
New Zealand E3 registration details
- Registration number
- AAC7191
- GEMS registration id
- 151475
- Status
- approved, available (self-reported)
- Registration expires
- 4 December 2027
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 10
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: reece.com.au. How the derived figures are calculated.