c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
4,507 kWh
487 cooling + 4,020 heating
Estimated running cost
$1,487 / year
$124 / month Β· $14,873 over 10 years
Capacity
10.2 kW cooling
10.9 kW heating

5% less electricity than the median of 136 comparable 10 kW reverse cycle ducted split system registrations (4,758 kWh a year) in the cold zone. Uses less than 71% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 43% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Carrier 38QSM105D8S running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,507$1,487$14,873
Mixed zone 2,262$746$7,465
Hot zone 2,246$741$7,412

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10.2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Panasonic U-100PZ3R5 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,660 kWh/yr4$1,208
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,687 kWh/yr3.5$1,217
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling3,713 kWh/yr5$1,225

Heat pumps similar to the Carrier 38QSM105D8S

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air URC-100DS / LRE-100DS12 kW heating10.2 kW cooling4,767 kWh/yr3.5$1,573
Midea UCMI90OC/DUCMI90IC12 kW heating10.2 kW cooling4,767 kWh/yr3.5$1,573
Daikin RZAV100CV1 / FBA100BVMA11.2 kW heating10 kW cooling4,295 kWh/yr3$1,417
Panasonic U-100PZ4R8 / S-100PE4*10 kW heating10 kW cooling3,866 kWh/yr2.5$1,276
Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling4,227 kWh/yr4.5$1,395
Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling3,866 kWh/yr2.5$1,276
Daikin RZAV100FY1 / FBA100BVMA12 kW heating10 kW cooling4,302 kWh/yr3.5$1,420
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling3,713 kWh/yr5$1,225

Compare 38QSM105D8S/42QSM105D8S with another model

Carrier 38QSM105D8S specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.15 kW
Cooling power input
3.23 kW
Rated heating capacity (7 Β°C)
10.87 kW
Heating power input
2.87 kW
EER, full load (tested)
3.31
COP, full load (tested)
4.18
Rated AEER
3.11
Rated ACOP
3.74
Standby power (PIA)
11.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Carrier 38QSM105D8S zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––-491,247
Coldresidential4.02.04874,020
Mixedcommercial––862641
Mixedresidential3.52.57841,478
Hotcommercial––1,536143
Hotresidential4.53.02,024222
Part-load test points (23 values)
c__t1_min_cap_power_rated
770 W
h__h1_min_cap_power_rated
500 W
h__h2_ext_cap_power_rated
3660 W
c__t1_half_cap_power_rated
1940 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1180 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2430 W
h__h2_ext_cap_heat_cap_rated
9700 W
h__h1_half_cap_heat_cap_rated
5530 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
390 W
c__t1_min_cap_cooling_cap_rated
2950 W
c__low_temp_half_cap_power_rated
860 W
c__t1_half_cap_cooling_cap_rated
5280 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2520 W
c__low_temp_half_cap_cooling_cap_rated
5100 W

New Zealand E3 registration details

Registration number
AAC10176
GEMS registration id
179578
Status
approved, available (self-reported)
Registration expires
2 August 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: midea.com.cn. How the derived figures are calculated.