c/kWh
Energy rating (cooling)
3.5
Heating: 0
Annual electricity use
2,019 kWh
Estimated running cost
$666 / year
$56 / month Β· $6,663 over 10 years
Capacity
40 kW cooling
40 kW heating

89% less electricity than the median of 19 comparable 40 kW reverse cycle multi-split / vrf registrations (18,821 kWh a year) in the cold zone. Uses less than 90% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 77% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Carrier 38VT014188QTSG running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,019$666$6,663
Mixed zone 3,201$1,056$10,563
Hot zone 9,475$3,127$31,268

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps similar to the Carrier 38VT014188QTSG

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Toshiba MMY-MAP1406FT8P-A40 kW heating40 kW cooling3,790 kWh/yr1$1,251
Toshiba MMY-MUP1401HT8P-A40 kW heating40 kW cooling2,257 kWh/yr3$745
Samsung Electronics AM140DXVGGR/SA45 kW heating40 kW cooling18,821 kWh/yr3$6,211
Mdv MV8-400WV2RN1E(MA)40 kW heating40 kW cooling21,407 kWh/yr2$7,064
Midea MV8-400WV2RN1E(MA)40 kW heating40 kW cooling21,407 kWh/yr2$7,064
Fujitsu AJY126LELBH40 kW heating40 kW cooling21,194 kWh/yr2.5$6,994
Hitachi RAS-14FSXNS45 kW heating40 kW cooling3,878 kWh/yr1$1,280
Samsung Electronics AM140DXVGGH/SA45 kW heating40 kW cooling18,821 kWh/yr3$6,211

Compare 38VT014188QTSG with another model

Carrier 38VT014188QTSG specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
40.00 kW
Cooling power input
10.23 kW
Rated heating capacity (7 Β°C)
40.00 kW
Heating power input
9.80 kW
EER, full load (tested)
3.76
COP, full load (tested)
3.91
Rated AEER
3.89
Rated ACOP
4.06
Standby power (PIA)
12.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China, Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Carrier 38VT014188QTSG zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––4,448–
Coldresidential3.50.02,019–
Mixedcommercial––5,638–
Mixedresidential3.50.03,201–
Hotcommercial––12,688–
Hotresidential4.00.09,475–
Part-load test points (5 values)
c__t1_half_cap_power_rated
3550 W
c__t1_have_min_cap_results
No
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
20000 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC9633
GEMS registration id
174085
Status
approved, available (self-reported)
Registration expires
3 December 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 21

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.