c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
18,821 kWh
2,268 cooling + 16,553 heating
Estimated running cost
$6,211 / year
$518 / month Β· $62,109 over 10 years
Capacity
40 kW cooling
45 kW heating

About the same electricity as the median of 19 comparable 40 kW reverse cycle multi-split / vrf registrations (18,821 kWh a year) in the cold zone. Uses less than 47% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 7% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Samsung Electronics AM140DXVGGH running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 18,821$6,211$62,109
Mixed zone 9,452$3,119$31,192
Hot zone 11,464$3,783$37,831

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 40 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Carrier 38VT014A88HTSG45 kW heating40 kW cooling2,005 kWh/yr3.5$662
Carrier 38VT014188QTSG40 kW heating40 kW cooling2,019 kWh/yr3.5$666
Toshiba MMY-MUP1401HT8P-A40 kW heating40 kW cooling2,257 kWh/yr3$745
Toshiba MMY-MAP1406FT8P-A40 kW heating40 kW cooling3,790 kWh/yr1$1,251
Hitachi RAS-14FSXNS45 kW heating40 kW cooling3,878 kWh/yr1$1,280

Heat pumps similar to the Samsung Electronics AM140DXVGGH

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea MV8-400WV2RN1E(MA)40 kW heating40 kW cooling21,407 kWh/yr2$7,064
Fujitsu AJY126LELBH40 kW heating40 kW cooling21,194 kWh/yr2.5$6,994
Hitachi RAS-14FSXNS45 kW heating40 kW cooling3,878 kWh/yr1$1,280
Carrier 38VT014188QTSG40 kW heating40 kW cooling2,019 kWh/yr3.5$666
Toshiba MMY-MAP1406FT8P-A40 kW heating40 kW cooling3,790 kWh/yr1$1,251
Carrier 38VT014A88HTSG45 kW heating40 kW cooling2,005 kWh/yr3.5$662
Toshiba MMY-MUP1401HT8P-A40 kW heating40 kW cooling2,257 kWh/yr3$745
Mdv MV8-400WV2RN1E(MA)40 kW heating40 kW cooling21,407 kWh/yr2$7,064

Compare AM140DXVGGH/SA with another model

Samsung Electronics AM140DXVGGH specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
40.00 kW
Cooling power input
11.27 kW
Rated heating capacity (7 Β°C)
45.00 kW
Heating power input
11.27 kW
EER, full load (tested)
3.55
COP, full load (tested)
4.00
Rated AEER
3.54
Rated ACOP
3.98
Standby power (PIA)
12.3 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
China, South Korea

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Samsung Electronics AM140DXVGGH zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––4,8425,212
Coldresidential3.02.02,26816,553
Mixedcommercial––6,1362,609
Mixedresidential3.02.53,5595,893
Hotcommercial––14,293506
Hotresidential3.03.010,662802
Part-load test points (24 values)
h__h1_min_cap_power_rated
2280 W
h__h2_ext_cap_power_rated
8530 W
c__t1_half_cap_power_rated
4230 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
4550 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
11420 W
h__h2_ext_cap_heat_cap_rated
32010 W
h__h1_half_cap_heat_cap_rated
22500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
1670 W
c__low_temp_full_cap_power_rated
10300.78 W
c__low_temp_half_cap_power_rated
3866.2200000000003 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
20000 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
10170 W
c__low_temp_full_cap_cooling_cap_rated
43080 W
c__low_temp_half_cap_cooling_cap_rated
21540 W

New Zealand E3 registration details

Registration number
AAC7684
GEMS registration id
155561
Status
approved, available (self-reported)
Registration expires
6 August 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 21

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.