New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, wall hung
Daikin RXV95L2VMA / FTXV95L2VMA Heat Pump
Daikin RXV95L2VMA / FTXV95L2VMA is a 9.4 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC6541).
- Energy rating (cooling)
- 2
- Heating: 1.5
- Annual electricity use
- 4,875 kWh
- 653 cooling + 4,222 heating
- Estimated running cost
- $1,609 / year
- $134 / month Β· $16,088 over 10 years
- Capacity
- 9.4 kW cooling
- 10.3 kW heating
10% more electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 21% of them.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 39% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Daikin RXV95L2VMA running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,875 | $1,609 | $16,088 |
| Mixed zone | 2,566 | $847 | $8,468 |
| Hot zone | 3,081 | $1,017 | $10,167 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 9.4 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr | 2.5 | $354 | |
| Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Fujitsu AOTH30KMTD/ASTH30KMTD9 kW heating8.5 kW cooling3,477 kWh/yr | 4 | $1,147 | |
| Fujitsu AOTH30KNTA/ASTH30KNTA9 kW heating8.5 kW cooling3,477 kWh/yr | 4 | $1,147 |
Heat pumps similar to the Daikin RXV95L2VMA
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| LG WH34SRU-18 / WH34SRN-1810.3 kW heating9.4 kW cooling4,477 kWh/yr | 3 | $1,477 | |
| Fujitsu AOTG34KMTC/ASTG34KMTC10.3 kW heating9.4 kW cooling4,650 kWh/yr | 2.5 | $1,535 | |
| Panasonic U-100PZH3R5/S-100PK3R9.5 kW heating9.5 kW cooling3,588 kWh/yr | 3 | $1,184 | |
| Fujitsu AOTH34KNTA/ASTH34KNTA10.3 kW heating9.5 kW cooling4,345 kWh/yr | 4 | $1,434 | |
| Mitsubishi Heavy Industries SRK95/DXK33ZRA-W10.3 kW heating9.5 kW cooling3,948 kWh/yr | 3.5 | $1,303 | |
| Mitsubishi Heavy Industries SRC95ZRA-W / SRK95ZRA-W10.3 kW heating9.5 kW cooling3,948 kWh/yr | 3.5 | $1,303 | |
| Panasonic U-100PZH3R8/S-100PK3R9.5 kW heating9.5 kW cooling3,588 kWh/yr | 3 | $1,184 |
Other Daikin models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RXM95P2VMA / FTXM95P2VMA10.3 kW heating9.4 kW cooling4,788 kWh/yr | 2.5 | $1,580 |
Compare RXV95L2VMA / FTXV95L2VMA with another model
Daikin RXV95L2VMA specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 9.40 kW
- Cooling power input
- 2.79 kW
- Rated heating capacity (7 Β°C)
- 10.30 kW
- Heating power input
- 3.07 kW
- EER, full load (tested)
- 3.45
- COP, full load (tested)
- 3.39
- Rated AEER
- 3.29
- Rated ACOP
- 3.28
- Standby power (PIA)
- 20.9 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 69 dB(A)
- Outdoor sound power
- 66 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Daikin RXV95L2VMA zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,383 | 1,342 |
| Coldresidential | residential | 2.0 | 1.5 | 653 | 4,222 |
| Mixedcommercial | commercial | β | β | 1,726 | 702 |
| Mixedresidential | residential | 2.0 | 2.0 | 1,001 | 1,565 |
| Hotcommercial | commercial | β | β | 3,772 | 171 |
| Hotresidential | residential | 2.5 | 2.5 | 2,824 | 257 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 3540 W
- c__t1_half_cap_power_rated
- 1080 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1120 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 8700 W
- h__h1_half_cap_heat_cap_rated
- 5150 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 2550.06 W
- c__low_temp_half_cap_power_rated
- 987.12 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 4700 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 10123.8 W
- c__low_temp_half_cap_cooling_cap_rated
- 5061.9 W
New Zealand E3 registration details
- Registration number
- AAC6541
- GEMS registration id
- 144605
- Status
- approved, available (self-reported)
- Registration expires
- 1 March 2027
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.