c/kWh
Energy rating (cooling)
2.5
Heating: 1.5
Annual electricity use
4,650 kWh
576 cooling + 4,074 heating
Estimated running cost
$1,535 / year
$128 / month Β· $15,345 over 10 years
Capacity
9.4 kW cooling
10.3 kW heating

5% more electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 39% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 42% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Fujitsu AOTG34KMTC running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,650$1,535$15,345
Mixed zone 2,472$816$8,158
Hot zone 2,887$953$9,527

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 9.4 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr2.5$354
Panasonic U-100PZ3R5 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Fujitsu AOTH30KMTD/ASTH30KMTD9 kW heating8.5 kW cooling3,477 kWh/yr4$1,147
Fujitsu AOTH30KNTA/ASTH30KNTA9 kW heating8.5 kW cooling3,477 kWh/yr4$1,147

Heat pumps similar to the Fujitsu AOTG34KMTC

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Daikin RXV95L2VMA / FTXV95L2VMA10.3 kW heating9.4 kW cooling4,875 kWh/yr2$1,609
Daikin RXM95P2VMA / FTXM95P2VMA10.3 kW heating9.4 kW cooling4,788 kWh/yr2.5$1,580
LG WH34SRU-18 / WH34SRN-1810.3 kW heating9.4 kW cooling4,477 kWh/yr3$1,477
Mitsubishi Heavy Industries SRC95ZRA-W / SRK95ZRA-W10.3 kW heating9.5 kW cooling3,948 kWh/yr3.5$1,303
Panasonic U-100PZH3R5/S-100PK3R9.5 kW heating9.5 kW cooling3,588 kWh/yr3$1,184
Mitsubishi Heavy Industries DXC33ZRA-W /DXK33ZRA-W10.3 kW heating9.5 kW cooling3,948 kWh/yr3.5$1,303
Panasonic U-100PZH3R8/S-100PK3R9.5 kW heating9.5 kW cooling3,588 kWh/yr3$1,184

Other Fujitsu models of similar capacity

ModelStarsEst. cost / yrCompare
Fujitsu AOTH34KMTD/ASTH34KMTD10.3 kW heating9.5 kW cooling4,345 kWh/yr4$1,434

Compare AOTG34KMTC/ASTG34KMTC with another model

Fujitsu AOTG34KMTC specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
9.40 kW
Cooling power input
2.78 kW
Rated heating capacity (7 Β°C)
10.30 kW
Heating power input
2.84 kW
EER, full load (tested)
3.49
COP, full load (tested)
3.75
Rated AEER
3.36
Rated ACOP
3.60
Standby power (PIA)
5.9 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
64 dB(A)
Outdoor sound power
65 dB(A)
Demand response (AS/NZS 4755)
No
Dimensions (WΓ—HΓ—D)
1150 Γ— 340 Γ— 280 mm
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Fujitsu AOTG34KMTC zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,2161,335
Coldresidential2.51.55764,074
Mixedcommercial––1,560713
Mixedresidential2.52.09041,568
Hotcommercial––3,505153
Hotresidential3.02.02,647240
Part-load test points (18 values)
h__h2_ext_cap_power_rated
4130 W
c__t1_half_cap_power_rated
1080 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1240 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
10370 W
h__h1_half_cap_heat_cap_rated
5150 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
950 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
4700 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
5130 W

New Zealand E3 registration details

Registration number
AAC8708
GEMS registration id
167863
Status
approved, available (self-reported)
Registration expires
31 March 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: fujitsugeneral.com.au. How the derived figures are calculated.