c/kWh
Energy rating (cooling)
2.5
Heating: 2
Annual electricity use
3,310 kWh
464 cooling + 2,846 heating
Estimated running cost
$1,092 / year
$91 / month Β· $10,923 over 10 years
Capacity
7.1 kW cooling
8 kW heating

1% more electricity than the median of 80 comparable 7 kW reverse cycle ducted split system registrations (3,279 kWh a year) in the cold zone. Uses less than 45% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 57% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Daikin RZAV71CV1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,310$1,092$10,923
Mixed zone 1,801$594$5,943
Hot zone 2,207$728$7,283

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ4R5 / S-6071PF3E6.8 kW heating6.8 kW cooling2,674 kWh/yr3$882
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,720 kWh/yr3.5$898
Aurora AU-BS24HR-2A-O / AU-LCF24-2A-I7.5 kW heating7.3 kW cooling2,720 kWh/yr3.5$898
Mdv C-UV-74N8-QC3W / CDV-74A6N8-QC3W7.5 kW heating7.4 kW cooling2,744 kWh/yr3.5$906
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,756 kWh/yr3$909

Heat pumps similar to the Daikin RZAV71CV1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hyundai HYDCTAC71TD7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914
Gree GFH24ACXF-S6DNE3D/O / GFH24ACXF-S6DNE3D/I7.6 kW heating7.1 kW cooling3,127 kWh/yr3$1,032
Braemar KCHB070D1B/KDHB070D1S7.6 kW heating7.1 kW cooling3,133 kWh/yr3$1,034
Panasonic U-71PZH3R5 / S-71PE4R8 kW heating7.1 kW cooling3,014 kWh/yr3$995
Panasonic U-71PZ4R5 / S-71PE4R7.1 kW heating7.1 kW cooling2,870 kWh/yr2.5$947
Hyundai HYDCTAC71TA7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914
Tosot TFH24ACXF-S6DNE3D/O / TFH24ACXF-S6DNE3D/I7.6 kW heating7.1 kW cooling3,127 kWh/yr3$1,032
TCL TCD71D1HWH-DVO/TCD71D1HWH-DVI7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914

Compare RZAV71CV1 / FBA71BVMA with another model

Daikin RZAV71CV1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.10 kW
Cooling power input
2.02 kW
Rated heating capacity (7 Β°C)
8.00 kW
Heating power input
1.99 kW
EER, full load (tested)
3.34
COP, full load (tested)
3.87
Rated AEER
3.43
Rated ACOP
3.93
Standby power (PIA)
14.1 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RZAV71CV1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––986932
Coldresidential2.52.04642,846
Mixedcommercial––1,232498
Mixedresidential2.02.57141,087
Hotcommercial––2,701122
Hotresidential3.02.52,022185
Part-load test points (16 values)
h__h2_ext_cap_power_rated
2200 W
c__t1_half_cap_power_rated
770 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
820 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
7050 W
h__h1_half_cap_heat_cap_rated
4000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3550 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC9827
GEMS registration id
176634
Status
approved, available (self-reported)
Registration expires
2 February 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.