c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
3,127 kWh
401 cooling + 2,726 heating
Estimated running cost
$1,032 / year
$86 / month Β· $10,319 over 10 years
Capacity
7.1 kW cooling
7.6 kW heating

5% less electricity than the median of 80 comparable 7 kW reverse cycle ducted split system registrations (3,279 kWh a year) in the cold zone. Uses less than 68% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 60% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Gree running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,127$1,032$10,319
Mixed zone 1,605$530$5,297
Hot zone 1,979$653$6,531

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ4R5 / S-6071PF3E6.8 kW heating6.8 kW cooling2,674 kWh/yr3$882
Aurora AU-BS24HR-2A-O / AU-LCF24-2A-I7.5 kW heating7.3 kW cooling2,720 kWh/yr3.5$898
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,720 kWh/yr3.5$898
Mdv C-UV-74N8-QC3W / CDV-74A6N8-QC3W7.5 kW heating7.4 kW cooling2,744 kWh/yr3.5$906
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,756 kWh/yr3$909

Heat pumps similar to the Gree

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
TCL TCD71D1HWH-DVO/TCD71D1HWH-DVI7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914
Panasonic U-71PZH3R5 / S-71PE4R8 kW heating7.1 kW cooling3,014 kWh/yr3$995
Hyundai HYDCTAC71T*7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914
Hyundai HYDCTAC71TC7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914
Daikin RZAS71C2V1 / FDYA71AV197.5 kW heating7.1 kW cooling2,974 kWh/yr3$981
Panasonic U-71PZ4R5 / S-71PE4R7.1 kW heating7.1 kW cooling2,870 kWh/yr2.5$947
Daikin RZAS71C2V1 / FDYUA71AV197.5 kW heating7.1 kW cooling2,974 kWh/yr3$981
Tosot TFH24ACXF-S6DNE3D/O / TFH24ACXF-S6DNE3D/I7.6 kW heating7.1 kW cooling3,127 kWh/yr3$1,032

Compare GFH24ACXF-S6DNE3D/O / GFH24ACXF-S6DNE3D/I with another model

Gree specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.10 kW
Cooling power input
1.97 kW
Rated heating capacity (7 Β°C)
7.60 kW
Heating power input
1.82 kW
EER, full load (tested)
3.56
COP, full load (tested)
4.22
Rated AEER
3.56
Rated ACOP
4.12
Standby power (PIA)
7.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––694852
Coldresidential3.02.04012,726
Mixedcommercial––943436
Mixedresidential3.02.5620985
Hotcommercial––2,37496
Hotresidential3.53.01,830149
Part-load test points (21 values)
c__t1_min_cap_power_rated
620 W
h__h1_min_cap_power_rated
355 W
h__h2_ext_cap_power_rated
2200 W
c__t1_half_cap_power_rated
750 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
750 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1720 W
h__h2_ext_cap_heat_cap_rated
6300 W
h__h1_half_cap_heat_cap_rated
3750 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
450 W
c__t1_min_cap_cooling_cap_rated
2800 W
c__t1_half_cap_cooling_cap_rated
3550 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
2900 W

1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
GFH24ACXF-S6DNE3D/O / GFH24ACXF-S6DNE3D/IAAC1015733,133

New Zealand E3 registration details

Registration number
AAC10252
GEMS registration id
180359
Status
approved, available (self-reported)
Registration expires
18 June 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.