New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Hyundai HYDCTAC71TD Heat Pump
Hyundai HYDCTAC71TD is a 7.1 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9363).
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 2,770 kWh
- 367 cooling + 2,403 heating
- Estimated running cost
- $914 / year
- $76 / month Β· $9,141 over 10 years
- Capacity
- 7.1 kW cooling
- 7.5 kW heating
15% less electricity than the median of 80 comparable 7 kW reverse cycle ducted split system registrations (3,279 kWh a year) in the cold zone. Uses less than 89% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 65% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Hyundai HYDCTAC71TD running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,770 | $914 | $9,141 |
| Mixed zone | 1,523 | $503 | $5,026 |
| Hot zone | 1,811 | $598 | $5,976 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 7.1 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-71PZ4R5 / S-6071PF3E6.8 kW heating6.8 kW cooling2,674 kWh/yr | 3 | $882 |
Heat pumps similar to the Hyundai HYDCTAC71TD
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Tosot TFH24ACXF-S6DNE3D/O / TFH24ACXF-S6DNE3D/I7.6 kW heating7.1 kW cooling3,127 kWh/yr | 3 | $1,032 | |
| Gree GFH24ACXF-S6DNE3D/O / GFH24ACXF-S6DNE3D/I7.6 kW heating7.1 kW cooling3,133 kWh/yr | 3 | $1,034 | |
| TCL TCD71D1HWH-DVO/TCD71D1HWH-DVI7.5 kW heating7.1 kW cooling2,770 kWh/yr | 3.5 | $914 | |
| Panasonic U-71PZH3R5 / S-71PE4R8 kW heating7.1 kW cooling3,014 kWh/yr | 3 | $995 | |
| Gree GFH24ACXF-S6DNE3D/O / GFH24ACXF-S6DNE3D/I7.6 kW heating7.1 kW cooling3,127 kWh/yr | 3 | $1,032 | |
| Panasonic U-71PZ4R5 / S-71PE4R7.1 kW heating7.1 kW cooling2,870 kWh/yr | 2.5 | $947 | |
| Daikin RZAS71C2V1 / FDYA71AV197.5 kW heating7.1 kW cooling2,974 kWh/yr | 3 | $981 | |
| Daikin RZAS71C2V1 / FDYUA71AV197.5 kW heating7.1 kW cooling2,974 kWh/yr | 3 | $981 |
Compare HYDCTAC71TD with another model
Hyundai HYDCTAC71TD specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 7.10 kW
- Cooling power input
- 1.90 kW
- Rated heating capacity (7 Β°C)
- 7.50 kW
- Heating power input
- 1.73 kW
- EER, full load (tested)
- 3.78
- COP, full load (tested)
- 4.41
- Rated AEER
- 3.69
- Rated ACOP
- 4.28
- Standby power (PIA)
- 7.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 66.3 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Hyundai HYDCTAC71TD zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 681 | 792 |
| Coldresidential | residential | 3.5 | 2.5 | 367 | 2,403 |
| Mixedcommercial | commercial | β | β | 916 | 430 |
| Mixedresidential | residential | 3.5 | 2.5 | 580 | 943 |
| Hotcommercial | commercial | β | β | 2,108 | 98 |
| Hotresidential | residential | 4.0 | 3.0 | 1,660 | 151 |
Part-load test points (18 values)
- h__h2_ext_cap_power_rated
- 3180 W
- c__t1_half_cap_power_rated
- 720 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 700 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 9000 W
- h__h1_half_cap_heat_cap_rated
- 3570 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 580 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 3500 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 3880 W
Other model numbers on registration AAC9363
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC9363
- GEMS registration id
- 172588
- Status
- approved, available (self-reported)
- Registration expires
- 31 August 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- HYDCTAC71T*
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 10
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.