c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
6,014 kWh
730 cooling + 5,284 heating
Estimated running cost
$1,985 / year
$165 / month Β· $19,846 over 10 years
Capacity
12.6 kW cooling
14.5 kW heating

9% more electricity than the median of 17 comparable 12.5 kW reverse cycle fixed registrations (5,528 kWh a year) in the cold zone. Uses less than 0% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 31% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Emerald ACR126U running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,014$1,985$19,846
Mixed zone 3,082$1,017$10,171
Hot zone 3,584$1,183$11,827

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 12.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Carrier 38QUM110D8S512.5 kW heating11.6 kW cooling4,367 kWh/yr3.5$1,441
Fujitsu AOTH45KBTA513.2 kW heating12.5 kW cooling4,625 kWh/yr4$1,526
Bonaire H5M125S1AE12.2 kW heating12.2 kW cooling4,758 kWh/yr3.5$1,570
TECO TSOM123HVAG512.6 kW heating12.3 kW cooling4,771 kWh/yr3.5$1,574
Midea MULMI0513B14 kW heating13.5 kW cooling4,925 kWh/yr4$1,625

Heat pumps similar to the Emerald ACR126U

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hisense AMW5-125U4RTAG14.2 kW heating12.6 kW cooling5,911 kWh/yr3$1,951
Fujitsu AOTG45LBLA613.5 kW heating12.5 kW cooling4,946 kWh/yr3.5$1,632
Fujitsu AOTH45KBTA513.2 kW heating12.5 kW cooling4,625 kWh/yr4$1,526
Hisense AMW5-125U4RTA13.5 kW heating12.5 kW cooling5,891 kWh/yr2.5$1,944
Bonaire H5M125S2AE13.5 kW heating12.3 kW cooling5,538 kWh/yr3$1,828
Hyundai HYSMHS12OTC13.5 kW heating12.3 kW cooling5,538 kWh/yr3$1,828
TECO TSOM123HVAG512.6 kW heating12.3 kW cooling4,771 kWh/yr3.5$1,574
Hyundai HYSMHS12OTB13.5 kW heating12.3 kW cooling5,538 kWh/yr3$1,828

Compare ACR126U with another model

Emerald ACR126U specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
12.60 kW
Cooling power input
3.50 kW
Rated heating capacity (7 Β°C)
14.50 kW
Heating power input
3.60 kW
EER, full load (tested)
3.48
COP, full load (tested)
3.78
Rated AEER
3.54
Rated ACOP
3.97
Standby power (PIA)
16.9 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
70.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Emerald ACR126U zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,5591,687
Coldresidential3.02.07305,284
Mixedcommercial––1,967874
Mixedresidential2.52.51,1431,939
Hotcommercial––4,367200
Hotresidential3.03.03,278306
Part-load test points (20 values)
h__h2_ext_cap_power_rated
5050 W
c__t1_half_cap_power_rated
1250 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1440 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
13000 W
h__h1_half_cap_heat_cap_rated
7200 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
3199 W
c__low_temp_half_cap_power_rated
1142.5 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
6500 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
13570.199999999999 W
c__low_temp_half_cap_cooling_cap_rated
7000.5 W

New Zealand E3 registration details

Registration number
AAC8571
GEMS registration id
166337
Status
approved, available (self-reported)
Registration expires
9 January 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. Manufacturer: emeraldplanet.com.au. How the derived figures are calculated.