c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
4,946 kWh
649 cooling + 4,297 heating
Estimated running cost
$1,632 / year
$136 / month Β· $16,322 over 10 years
Capacity
12.5 kW cooling
13.5 kW heating

10% less electricity than the median of 17 comparable 12.5 kW reverse cycle fixed registrations (5,528 kWh a year) in the cold zone. Uses less than 71% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 39% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Fujitsu AOTG45LBLA6 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,946$1,632$16,322
Mixed zone 2,664$879$8,791
Hot zone 3,267$1,078$10,781

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 12.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Carrier 38QUM110D8S512.5 kW heating11.6 kW cooling4,367 kWh/yr3.5$1,441
Fujitsu AOTH45KBTA513.2 kW heating12.5 kW cooling4,625 kWh/yr4$1,526
Bonaire H5M125S1AE12.2 kW heating12.2 kW cooling4,758 kWh/yr3.5$1,570
TECO TSOM123HVAG512.6 kW heating12.3 kW cooling4,771 kWh/yr3.5$1,574

Heat pumps similar to the Fujitsu AOTG45LBLA6

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hisense AMW5-125U4RTA13.5 kW heating12.5 kW cooling5,891 kWh/yr2.5$1,944
Emerald ACR126U14.5 kW heating12.6 kW cooling6,014 kWh/yr3$1,985
Hisense AMW5-125U4RTAG14.2 kW heating12.6 kW cooling5,911 kWh/yr3$1,951
Bonaire H5M125S2AE13.5 kW heating12.3 kW cooling5,538 kWh/yr3$1,828
Hyundai HYSMHS12OTA13.5 kW heating12.3 kW cooling5,538 kWh/yr3$1,828
Hyundai HYSMHS12OTB13.5 kW heating12.3 kW cooling5,538 kWh/yr3$1,828
TECO TSOM123HVAG512.6 kW heating12.3 kW cooling4,771 kWh/yr3.5$1,574

Other Fujitsu models of similar capacity

ModelStarsEst. cost / yrCompare
Fujitsu AOTH45KBTA513.2 kW heating12.5 kW cooling4,625 kWh/yr4$1,526

Compare AOTG45LBLA6 with another model

Fujitsu AOTG45LBLA6 specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
12.50 kW
Cooling power input
3.57 kW
Rated heating capacity (7 Β°C)
13.50 kW
Heating power input
3.37 kW
EER, full load (tested)
3.52
COP, full load (tested)
4.04
Rated AEER
3.47
Rated ACOP
3.96
Standby power (PIA)
10.5 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
68 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Fujitsu AOTG45LBLA6 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,3731,367
Coldresidential3.52.56494,297
Mixedcommercial––1,758719
Mixedresidential3.03.01,0411,623
Hotcommercial––3,992158
Hotresidential3.53.53,022245
Part-load test points (16 values)
h__h2_ext_cap_power_rated
5000 W
c__t1_half_cap_power_rated
1050 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1190 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
14400 W
h__h1_half_cap_heat_cap_rated
6750 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
6250 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC8670
GEMS registration id
167905
Status
approved, available (self-reported)
Registration expires
31 March 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: fujitsugeneral.com.au. How the derived figures are calculated.