c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
7,466 kWh
789 cooling + 6,677 heating
Estimated running cost
$2,464 / year
$205 / month Β· $24,638 over 10 years
Capacity
15.5 kW cooling
21 kW heating

3% less electricity than the median of 30 comparable 16 kW reverse cycle multi-split / vrf registrations (7,713 kWh a year) in the cold zone. Uses less than 57% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 22% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Ers Tech ERS-AC24KWH-G running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 7,466$2,464$24,638
Mixed zone 3,683$1,215$12,154
Hot zone 3,761$1,241$12,411

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 15.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXYMQ5BVM14 kW heating14 kW cooling5,792 kWh/yr2.5$1,911
Daikin RXYMQ5B2VM14 kW heating14 kW cooling5,795 kWh/yr2.5$1,912
Silicon Electronics EMV-V170W/N117 kW heating17 kW cooling5,813 kWh/yr3.5$1,918
Smart User SMV-V170W/N117 kW heating17 kW cooling5,813 kWh/yr3.5$1,918
Smart User SMV-V170W/N117 kW heating17 kW cooling5,819 kWh/yr3.5$1,920

Heat pumps similar to the Ers Tech ERS-AC24KWH-G

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38VS006181HCSG18 kW heating15.5 kW cooling7,284 kWh/yr3$2,404
Metro Heating & Cooling MHC-AC24KWH21 kW heating15.5 kW cooling7,466 kWh/yr3.5$2,464
Hisense AVW-54HJFAH117 kW heating15.5 kW cooling7,192 kWh/yr3$2,373
Gree GMV-160WL/B-T(A)21 kW heating15.5 kW cooling7,466 kWh/yr3.5$2,464
Smart User SMV-V180W/N119 kW heating15.5 kW cooling5,831 kWh/yr4$1,924
Spt AV210C-921 kW heating15.5 kW cooling7,398 kWh/yr3.5$2,441
Midea MDV-V160WHN8(At)15.5 kW heating15.5 kW cooling7,012 kWh/yr2$2,314
Toshiba MCY-MHP0604HS-A18 kW heating15.5 kW cooling7,284 kWh/yr3$2,404

Compare ERS-AC24KWH-G with another model

Ers Tech ERS-AC24KWH-G specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
15.50 kW
Cooling power input
3.31 kW
Rated heating capacity (7 Β°C)
21.00 kW
Heating power input
5.15 kW
EER, full load (tested)
4.69
COP, full load (tested)
4.17
Rated AEER
4.55
Rated ACOP
4.00
Standby power (PIA)
28.5 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
52 dB(A)
Outdoor sound power
69.7 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Ers Tech ERS-AC24KWH-G zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,6592,070
Coldresidential3.52.57896,677
Mixedcommercial––2,0671,072
Mixedresidential3.53.01,2062,477
Hotcommercial––4,503252
Hotresidential4.04.03,375386
Part-load test points (24 values)
h__h1_min_cap_power_rated
720 W
h__h2_ext_cap_power_rated
6300 W
c__t1_half_cap_power_rated
1280 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1810 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
4630 W
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
Yes
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
4100 W
h__h2_ext_cap_heat_cap_rated
19650 W
h__h1_half_cap_heat_cap_rated
10250 W
h__h2_full_cap_heat_cap_rated
16600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
3025.34 W
c__low_temp_half_cap_power_rated
1169.92 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
7700 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
16693.5 W
c__low_temp_half_cap_cooling_cap_rated
8292.9 W

New Zealand E3 registration details

Registration number
AAC7977
GEMS registration id
158702
Status
approved, available (self-reported)
Registration expires
19 December 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.