New Zealand Β· costs in NZD

Reverse cycle multi-split / vrf air conditioner
Spt AV210C-9 Heat Pump
Spt AV210C-9 is a 15.5 kW reverse cycle multi-split / vrf heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8380).
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 7,398 kWh
- 782 cooling + 6,616 heating
- Estimated running cost
- $2,441 / year
- $203 / month Β· $24,413 over 10 years
- Capacity
- 15.5 kW cooling
- 21 kW heating
4% less electricity than the median of 30 comparable 16 kW reverse cycle multi-split / vrf registrations (7,713 kWh a year) in the cold zone. Uses less than 67% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 22% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Spt AV210C-9 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 7,398 | $2,441 | $24,413 |
| Mixed zone | 3,640 | $1,201 | $12,012 |
| Hot zone | 3,715 | $1,226 | $12,260 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 15.5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RXYMQ5BVM14 kW heating14 kW cooling5,792 kWh/yr | 2.5 | $1,911 | |
| Daikin RXYMQ5B2VM14 kW heating14 kW cooling5,795 kWh/yr | 2.5 | $1,912 | |
| Silicon Electronics EMV-V170W/N117 kW heating17 kW cooling5,813 kWh/yr | 3.5 | $1,918 | |
| Smart User SMV-V170W/N117 kW heating17 kW cooling5,813 kWh/yr | 3.5 | $1,918 | |
| Smart User SMV-V170W/N117 kW heating17 kW cooling5,819 kWh/yr | 3.5 | $1,920 |
Heat pumps similar to the Spt AV210C-9
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier 38VS006181HCSG18 kW heating15.5 kW cooling7,284 kWh/yr | 3 | $2,404 | |
| Metro Heating & Cooling MHC-AC24KWH21 kW heating15.5 kW cooling7,466 kWh/yr | 3.5 | $2,464 | |
| Actron Air MMV-160CS18 kW heating15.5 kW cooling7,713 kWh/yr | 2.5 | $2,545 | |
| Ers Tech ERS-AC24KWH19.5 kW heating15.5 kW cooling6,060 kWh/yr | 4 | $2,000 | |
| Hisense AVW-54HJFAH117 kW heating15.5 kW cooling7,192 kWh/yr | 3 | $2,373 | |
| Smart User SMV-V180W/N119 kW heating15.5 kW cooling5,831 kWh/yr | 4 | $1,924 | |
| Midea MDV-V160WHN8(At)15.5 kW heating15.5 kW cooling7,012 kWh/yr | 2 | $2,314 | |
| Toshiba MCY-MHP0604HS-A18 kW heating15.5 kW cooling7,284 kWh/yr | 3 | $2,404 |
Compare AV210C-9 with another model
Spt AV210C-9 specifications
- Type
- Reverse cycle
- Configuration
- Multi-split / VRF
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 15.50 kW
- Cooling power input
- 3.20 kW
- Rated heating capacity (7 Β°C)
- 21.00 kW
- Heating power input
- 5.15 kW
- EER, full load (tested)
- 4.69
- COP, full load (tested)
- 4.17
- Rated AEER
- 4.70
- Rated ACOP
- 4.00
- Standby power (PIA)
- 28.5 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 69.7 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Spt AV210C-9 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,650 | 2,051 |
| Coldresidential | residential | 3.5 | 2.5 | 782 | 6,616 |
| Mixedcommercial | commercial | β | β | 2,052 | 1,061 |
| Mixedresidential | residential | 3.5 | 3.0 | 1,191 | 2,449 |
| Hotcommercial | commercial | β | β | 4,453 | 250 |
| Hotresidential | residential | 4.0 | 4.0 | 3,332 | 383 |
Part-load test points (24 values)
- h__h1_min_cap_power_rated
- 720 W
- h__h2_ext_cap_power_rated
- 6300 W
- c__t1_half_cap_power_rated
- 1280 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1810 W
- h__h1_have_min_cap_results
- Yes
- h__h2_full_cap_power_rated
- 4600 W
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- Yes
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 4150 W
- h__h2_ext_cap_heat_cap_rated
- 19650 W
- h__h1_half_cap_heat_cap_rated
- 10350 W
- h__h2_full_cap_heat_cap_rated
- 16700 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 2924.8 W
- c__low_temp_half_cap_power_rated
- 1169.92 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 7700 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 16693.5 W
- c__low_temp_half_cap_cooling_cap_rated
- 8292.9 W
New Zealand E3 registration details
- Registration number
- AAC8380
- GEMS registration id
- 163680
- Status
- approved, available (self-reported)
- Registration expires
- 5 August 2029
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- Class 20
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.