c/kWh
Energy rating (cooling)
0
Heating: 0
Annual electricity use
4,370 kWh
859 cooling + 3,511 heating
Estimated running cost
$1,442 / year
$120 / month Β· $14,421 over 10 years
Capacity
4.1 kW cooling
3.3 kW heating

21% more electricity than the median of 24 comparable 3.5 kW reverse cycle portable registrations (3,602 kWh a year) in the cold zone. Uses less than 4% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 44% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Excelair EPA58041RWB running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,370$1,442$14,421
Mixed zone 3,029$1,000$9,996
Hot zone 3,910$1,290$12,903

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 4.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hyundai HY13KSPACP*2.8 kW heating3.8 kW cooling3,775 kWh/yr0$1,246
Hyundai HY13KSPACPD2.8 kW heating3.8 kW cooling3,775 kWh/yr0$1,246
Ausclimate Ausclimate 14K PAC2.9 kW heating4.2 kW cooling3,936 kWh/yr0$1,299
Ausclimate ACPAC2402.9 kW heating4.2 kW cooling3,936 kWh/yr0$1,299
Goldair PAC13493.2 kW heating4.1 kW cooling3,984 kWh/yr0$1,315

Heat pumps similar to the Excelair EPA58041RWB

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Dimplex DPRC41ECO-C3.4 kW heating4.1 kW cooling4,361 kWh/yr0$1,439
Goldair PAC13493.2 kW heating4.1 kW cooling3,984 kWh/yr0$1,315
Goldair 4.1kW Hot & Cold Portable Air Conditioner3.2 kW heating4.1 kW cooling3,984 kWh/yr0$1,315
Modello MODPA013.3 kW heating4.1 kW cooling4,170 kWh/yr0$1,376
Bonaire PRC60001413.1 kW heating4 kW cooling4,143 kWh/yr0$1,367
Ausclimate ACPAC2402.9 kW heating4.2 kW cooling3,936 kWh/yr0$1,299
Ausclimate Ausclimate 14K PAC2.9 kW heating4.2 kW cooling3,936 kWh/yr0$1,299
TECO TPO42HVWAH3.9 kW heating4.2 kW cooling4,487 kWh/yr0$1,481

Compare EPA58041RWB with another model

Excelair EPA58041RWB specifications

Type
Reverse cycle
Configuration
Portable
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
4.10 kW
Cooling power input
1.58 kW
Rated heating capacity (7 Β°C)
3.30 kW
Heating power input
1.32 kW
EER, full load (tested)
2.61
COP, full load (tested)
2.50
Rated AEER
2.60
Rated ACOP
2.50
Standby power (PIA)
–
Compressor
Fixed speed
Refrigerant
R290
Power supply
Single phase
Indoor sound power
62.9 dB(A)
Outdoor sound power
–
Demand response (AS/NZS 4755)
–
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Excelair EPA58041RWB zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldresidential0.00.08593,511
Mixedresidential0.00.01,3251,704
Hotresidential0.00.03,544366

New Zealand E3 registration details

Registration number
AAC8397
GEMS registration id
163442
Status
approved, available (self-reported)
Registration expires
13 August 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[Unitary Single-Duct] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.5:2015
MEPS
2019
Product class
Class 4

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.