c/kWh
Energy rating (cooling)
0
Heating: 0
Annual electricity use
3,984 kWh
872 cooling + 3,112 heating
Estimated running cost
$1,315 / year
$110 / month Β· $13,147 over 10 years
Capacity
4.1 kW cooling
3.2 kW heating

11% more electricity than the median of 24 comparable 3.5 kW reverse cycle portable registrations (3,602 kWh a year) in the cold zone. Uses less than 21% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 47% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Goldair GPPAC410 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,984$1,315$13,147
Mixed zone 2,854$942$9,418
Hot zone 3,919$1,293$12,933

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 4.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hyundai HY13KSPACP*2.8 kW heating3.8 kW cooling3,775 kWh/yr0$1,246
Hyundai HY13KSPACPD2.8 kW heating3.8 kW cooling3,775 kWh/yr0$1,246

Heat pumps similar to the Goldair GPPAC410

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Excelair EPA58041RWB3.3 kW heating4.1 kW cooling4,370 kWh/yr0$1,442
Dimplex DPRC41ECO-C3.4 kW heating4.1 kW cooling4,361 kWh/yr0$1,439
Modello MODPA013.3 kW heating4.1 kW cooling4,170 kWh/yr0$1,376
Bonaire PRC60001413.1 kW heating4 kW cooling4,143 kWh/yr0$1,367
Ausclimate Ausclimate 14K PAC2.9 kW heating4.2 kW cooling3,936 kWh/yr0$1,299
TECO TPO42HVWAH3.9 kW heating4.2 kW cooling4,487 kWh/yr0$1,481
Ausclimate ACPAC2402.9 kW heating4.2 kW cooling3,936 kWh/yr0$1,299
Hyundai HY13KSPACPD2.8 kW heating3.8 kW cooling3,775 kWh/yr0$1,246

Compare GPPAC410 with another model

Goldair GPPAC410 specifications

Type
Reverse cycle
Configuration
Portable
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
4.10 kW
Cooling power input
1.60 kW
Rated heating capacity (7 Β°C)
3.20 kW
Heating power input
1.17 kW
EER, full load (tested)
2.61
COP, full load (tested)
3.14
Rated AEER
2.56
Rated ACOP
2.74
Standby power (PIA)
–
Compressor
Fixed speed
Refrigerant
R290
Power supply
Single phase
Indoor sound power
70.4 dB(A)
Outdoor sound power
–
Demand response (AS/NZS 4755)
–
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Goldair GPPAC410 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldresidential0.00.08723,112
Mixedresidential0.00.01,3441,510
Hotresidential0.00.03,595324

Other model numbers on registration AAC9403

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC9403
GEMS registration id
171933
Status
approved, available (self-reported)
Registration expires
8 September 2030
Registered for sale in
Australia, New Zealand
Family
4.1kW Hot & Cold Portable Air Conditioner
Regulatory standard
[Unitary Single-Duct] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.5:2015
MEPS
2019
Product class
Class 4

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.