c/kWh
Energy rating (cooling)
3
Heating: 1.5
Annual electricity use
2,346 kWh
226 cooling + 2,120 heating
Estimated running cost
$774 / year
$65 / month Β· $7,742 over 10 years
Capacity
4.2 kW cooling
5.4 kW heating

68% more electricity than the median of 187 comparable 3.5 kW reverse cycle split system registrations (1,395 kWh a year) in the cold zone. Uses less than 0% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 71% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Fujitsu AOTG14LUCB running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,346$774$7,742
Mixed zone 1,106$365$3,650
Hot zone 1,135$375$3,746

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 4.2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hisense HAWU12KR3.9 kW heating3.7 kW cooling1,332 kWh/yr6$440
Hisense HAWH12KR3.9 kW heating3.7 kW cooling1,360 kWh/yr5$449
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Toshiba RAS-13U2AVSG-NZ / RAS-13U2FVG-NZ4.2 kW heating4 kW cooling1,756 kWh/yr4$579

Heat pumps similar to the Fujitsu AOTG14LUCB

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic CU-*Z42DKR / CS-*Z42DKRW5 kW heating4.2 kW cooling1,969 kWh/yr3.5$650
Mitsubishi Heavy Industries SRC42ZTA-W/SRK42ZTA-WF5.4 kW heating4.2 kW cooling1,950 kWh/yr4.5$644
Toshiba RAS-16ZAVSG-A / RAS-16ZKVSG-A5.4 kW heating4.2 kW cooling2,099 kWh/yr4$693
Mitsubishi Electric MUZ-AP42VG2/MSZ-AP42VGKD25.4 kW heating4.2 kW cooling2,017 kWh/yr4$666
Mitsubishi Electric MUZ-AP42VGD2/MSZ-AP42VGD25.4 kW heating4.2 kW cooling2,017 kWh/yr4$666
Toshiba RAS-16E2AVG-A/RAS-16E2KV2G-A5.4 kW heating4.2 kW cooling2,324 kWh/yr3$767
Mitsubishi Heavy Industries SRC42ZTA-WB/SRK42ZTA-WF5.4 kW heating4.2 kW cooling1,950 kWh/yr4.5$644
Panasonic CU-Z42DKR / CS-Z42DKRW5 kW heating4.2 kW cooling1,969 kWh/yr3.5$650

Compare AOTG14LUCB/ASTG14LUCB with another model

Fujitsu AOTG14LUCB specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
4.20 kW
Cooling power input
1.25 kW
Rated heating capacity (7 Β°C)
5.40 kW
Heating power input
1.47 kW
EER, full load (tested)
3.38
COP, full load (tested)
3.78
Rated AEER
3.31
Rated ACOP
3.63
Standby power (PIA)
5.2 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
62 dB(A)
Outdoor sound power
67 dB(A)
Demand response (AS/NZS 4755)
No
Dimensions (WΓ—HΓ—D)
870 Γ— 282 Γ— 185 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Fujitsu AOTG14LUCB zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––425667
Coldresidential3.01.52262,120
Mixedcommercial––568322
Mixedresidential3.02.5361745
Hotcommercial––1,30970
Hotresidential3.53.01,027108
Part-load test points (18 values)
h__h2_ext_cap_power_rated
1470 W
c__t1_half_cap_power_rated
400 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
515 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
4000 W
h__h1_half_cap_heat_cap_rated
2700 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
330 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
2100 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
2262 W

New Zealand E3 registration details

Registration number
AAC8716
GEMS registration id
167855
Status
approved, available (self-reported)
Registration expires
31 March 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: fujitsugeneral.com.au. How the derived figures are calculated.