c/kWh
Energy rating (cooling)
2.5
Heating: 1.5
Annual electricity use
1,721 kWh
217 cooling + 1,504 heating
Estimated running cost
$568 / year
$47 / month Β· $5,679 over 10 years
Capacity
3.5 kW cooling
4 kW heating

3% more electricity than the median of 12 comparable 3.5 kW reverse cycle ducted split system registrations (1,675 kWh a year) in the cold zone. Uses less than 33% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 79% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Fujitsu AOTH12KBTA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,721$568$5,679
Mixed zone 899$297$2,967
Hot zone 1,065$351$3,515

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 3.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-36PZ3R5 / S-3650PF3E3.6 kW heating3.4 kW cooling1,377 kWh/yr2.5$454
Mitsubishi Electric SUZ-M35VAD-A/SEZ-M35DAL4 kW heating3.5 kW cooling1,539 kWh/yr2.5$508
Mitsubishi Electric SUZ-M35VAD-A/SEZ-M35DAL34 kW heating3.5 kW cooling1,539 kWh/yr2.5$508
Daikin RZAC35GV1 / FDYBA35AV14 kW heating3.5 kW cooling1,662 kWh/yr2$548
Fujitsu AOTH12KBTA/ARTH12KLLAP4 kW heating3.5 kW cooling1,663 kWh/yr2.5$549

Heat pumps similar to the Fujitsu AOTH12KBTA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Daikin RZAC35G2V1 / FDYBA35AV14 kW heating3.5 kW cooling1,666 kWh/yr2$550
Mitsubishi Electric SUZ-M35VAD2-A/SEZ-M35DA34 kW heating3.5 kW cooling1,539 kWh/yr2.5$508
Daikin RZAC35GV1 / FDYBA35AV14 kW heating3.5 kW cooling1,662 kWh/yr2$548
Mitsubishi Electric SUZ-M35VAD-A/SEZ-M35DAL34 kW heating3.5 kW cooling1,539 kWh/yr2.5$508
Gree GFH12KAXD-S6DNK1A/O / GFH12KAXD-S6DNK1A/I4.2 kW heating3.5 kW cooling1,889 kWh/yr3$623
Tosot TFH12KAXD-S6DNK1A/O / TFH12KAXD-S6DNK1A/I4.2 kW heating3.5 kW cooling1,889 kWh/yr3$623

Other Fujitsu models of similar capacity

ModelStarsEst. cost / yrCompare
Fujitsu AOTH12KBTA/ARTH12KLLAP4 kW heating3.5 kW cooling1,663 kWh/yr2.5$549
Fujitsu AOTG12LBCA/ARTG12LLLB4.5 kW heating3.5 kW cooling1,846 kWh/yr2$609

Compare AOTH12KBTA/ARTH12KSLAP with another model

Fujitsu AOTH12KBTA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
3.50 kW
Cooling power input
0.98 kW
Rated heating capacity (7 Β°C)
4.00 kW
Heating power input
1.10 kW
EER, full load (tested)
3.63
COP, full load (tested)
3.78
Rated AEER
3.53
Rated ACOP
3.60
Standby power (PIA)
3.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Dimensions (WΓ—HΓ—D)
900 Γ— 198 Γ— 620 mm
Country of manufacture
China, Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Fujitsu AOTH12KBTA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––475480
Coldresidential2.51.52171,504
Mixedcommercial––595251
Mixedresidential2.52.0337562
Hotcommercial––1,31555
Hotresidential3.02.597986
Part-load test points (16 values)
h__h2_ext_cap_power_rated
1500 W
c__t1_half_cap_power_rated
380 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
420 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
3800 W
h__h1_half_cap_heat_cap_rated
2000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1750 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC9756
GEMS registration id
176049
Status
approved, available (self-reported)
Registration expires
24 January 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: fujitsugeneral.com.au. How the derived figures are calculated.