New Zealand Β· costs in NZD
Reverse cycle split system air conditioner
Gree GFH12KAXD-S6DNK1A/O / GFH12KAXD-S6DNK1A/I Heat Pump
Gree GFH12KAXD-S6DNK1A/O / GFH12KAXD-S6DNK1A/I is a 3.5 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9937).
- Energy rating (cooling)
- 3
- Heating: 1.5
- Annual electricity use
- 1,889 kWh
- 202 cooling + 1,687 heating
- Estimated running cost
- $623 / year
- $52 / month Β· $6,234 over 10 years
- Capacity
- 3.5 kW cooling
- 4.2 kW heating
13% more electricity than the median of 12 comparable 3.5 kW reverse cycle ducted split system registrations (1,675 kWh a year) in the cold zone. Uses less than 8% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 78% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Gree running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 1,889 | $623 | $6,234 |
| Mixed zone | 943 | $311 | $3,112 |
| Hot zone | 1,016 | $335 | $3,353 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 3.5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-36PZ3R5 / S-3650PF3E3.6 kW heating3.4 kW cooling1,377 kWh/yr | 2.5 | $454 | |
| Mitsubishi Electric SUZ-M35VAD-A/SEZ-M35DA4 kW heating3.5 kW cooling1,539 kWh/yr | 2.5 | $508 | |
| Mitsubishi Electric SUZ-M35VAD2-A/SEZ-M35DA34 kW heating3.5 kW cooling1,539 kWh/yr | 2.5 | $508 | |
| Daikin RZAC35GV1 / FDYBA35AV14 kW heating3.5 kW cooling1,662 kWh/yr | 2 | $548 | |
| Fujitsu AOTH12KBTA/ARTH12KLLAP4 kW heating3.5 kW cooling1,663 kWh/yr | 2.5 | $549 |
Heat pumps similar to the Gree
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Tosot TFH12KAXD-S6DNK1A/O / TFH12KAXD-S6DNK1A/I4.2 kW heating3.5 kW cooling1,889 kWh/yr | 3 | $623 | |
| Mitsubishi Electric SUZ-M35VAD-A/SEZ-M35DAL34 kW heating3.5 kW cooling1,539 kWh/yr | 2.5 | $508 | |
| Fujitsu AOTH12KBTA/ARTH12KLLAP4 kW heating3.5 kW cooling1,663 kWh/yr | 2.5 | $549 | |
| Mitsubishi Electric SUZ-M35VAD2-A/SEZ-M35DA34 kW heating3.5 kW cooling1,539 kWh/yr | 2.5 | $508 | |
| Fujitsu AOTH12KBTA/ARTH12KSLAP4 kW heating3.5 kW cooling1,721 kWh/yr | 2.5 | $568 | |
| Daikin RZAC35G2V1 / FDYBA35AV14 kW heating3.5 kW cooling1,666 kWh/yr | 2 | $550 | |
| Daikin RZAC35GV1 / FDYBA35AV14 kW heating3.5 kW cooling1,662 kWh/yr | 2 | $548 | |
| Panasonic U-36PZ3R5 / S-3650PF3E3.6 kW heating3.4 kW cooling1,377 kWh/yr | 2.5 | $454 |
Compare GFH12KAXD-S6DNK1A/O / GFH12KAXD-S6DNK1A/I with another model
Gree specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 3.52 kW
- Cooling power input
- 1.01 kW
- Rated heating capacity (7 Β°C)
- 4.20 kW
- Heating power input
- 1.17 kW
- EER, full load (tested)
- 3.64
- COP, full load (tested)
- 3.62
- Rated AEER
- 3.43
- Rated ACOP
- 3.57
- Standby power (PIA)
- 3.3 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Gree zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 353 | 554 |
| Coldresidential | residential | 3.0 | 1.5 | 202 | 1,687 |
| Mixedcommercial | commercial | β | β | 481 | 297 |
| Mixedresidential | residential | 3.0 | 2.0 | 315 | 628 |
| Hotcommercial | commercial | β | β | 1,159 | 65 |
| Hotresidential | residential | 3.0 | 2.0 | 919 | 97 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 215 W
- h__h1_min_cap_power_rated
- 145 W
- h__h2_ext_cap_power_rated
- 1300 W
- c__t1_half_cap_power_rated
- 410 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 450 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 450 W
- h__h2_ext_cap_heat_cap_rated
- 3500 W
- h__h1_half_cap_heat_cap_rated
- 2050 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 170 W
- c__t1_min_cap_cooling_cap_rated
- 900 W
- c__low_temp_half_cap_power_rated
- 310 W
- c__t1_half_cap_cooling_cap_rated
- 1730 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 1060 W
- c__low_temp_half_cap_cooling_cap_rated
- 1730 W
New Zealand E3 registration details
- Registration number
- AAC9937
- GEMS registration id
- 177496
- Status
- approved, available (self-reported)
- Registration expires
- 12 March 2031
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 10
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.