c/kWh
Energy rating (cooling)
1
Heating: 1
Annual electricity use
6,677 kWh
910 cooling + 5,767 heating
Estimated running cost
$2,203 / year
$184 / month Β· $22,034 over 10 years
Capacity
10 kW cooling
11 kW heating

Only 3 comparable registrations in this cohort, so no percentile is shown.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 26% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Gree GMV-100WL running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,677$2,203$22,034
Mixed zone 3,627$1,197$11,969
Hot zone 4,115$1,358$13,580

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric PUMY-SP80YKMD2-A10 kW heating9 kW cooling4,656 kWh/yr2$1,536
Mitsubishi Electric PUMY-SP80YKMD2-A-BS10 kW heating9 kW cooling4,656 kWh/yr2$1,536

Heat pumps similar to the Gree GMV-100WL

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric PUMY-SP80YKMD2-A10 kW heating9 kW cooling4,656 kWh/yr2$1,536
Mitsubishi Electric PUMY-SP80YKMD2-A-BS10 kW heating9 kW cooling4,656 kWh/yr2$1,536

Compare GMV-100WL/A-T(A) with another model

Gree GMV-100WL specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
3.10 kW
Rated heating capacity (7 Β°C)
11.00 kW
Heating power input
3.00 kW
EER, full load (tested)
3.25
COP, full load (tested)
3.52
Rated AEER
3.09
Rated ACOP
3.51
Standby power (PIA)
40.4 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
65.3 dB(A)
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree GMV-100WL zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,9391,891
Coldresidential1.01.09105,767
Mixedcommercial––2,3771,039
Mixedresidential1.01.01,3542,273
Hotcommercial––5,006270
Hotresidential1.51.53,713402
Part-load test points (14 values)
c__t1_half_cap_power_rated
1550 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1650 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
3500 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
5500 W
h__h2_full_cap_heat_cap_rated
8000 W
h__h2_is_capable_extended_load
No
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5000 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC9401
GEMS registration id
171918
Status
approved, available (self-reported)
Registration expires
8 September 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.